{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/30137"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/30137","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"The retrofitting of existing buildings for seismic criteria","abstract":"This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the procedure for retrofitting a building. This procedure begins with acquiring information about the existing building and its surroundings. The building owner or client then needs to work with the design professional to establish an acceptable performance level, or rehabilitation objective. A rehabilitation method must then be selected that determines how the building should be analyzed. The analysis of the building, including suggested rehabilitation strategies, must then be performed. Once the analysis indicates that the building will perform to its prescribed performance level, the rehabilitation strategies must then be implemented. The thesis ends with a description of two buildings that have recently been retrofitted, or are in the processes of being retrofitted. It gives an overview of the selected rehabilitation strategies and the reasoning behind their selection.","abstract_html":"This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the procedure for retrofitting a building. This procedure begins with acquiring information about the existing building and its surroundings. The building owner or client then needs to work with the design professional to establish an acceptable performance level, or rehabilitation objective. A rehabilitation method must then be selected that determines how the building should be analyzed. The analysis of the building, including suggested rehabilitation strategies, must then be performed. Once the analysis indicates that the building will perform to its prescribed performance level, the rehabilitation strategies must then be implemented. The thesis ends with a description of two buildings that have recently been retrofitted, or are in the processes of being retrofitted. It gives an overview of the selected rehabilitation strategies and the reasoning behind their selection.","abstract_has_math":false,"creators":["Besing, Christa, 1978-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.","school":null,"contributors":[],"advisors":["Jerome J Connor."],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-07-22T22:22:18Z","subjects":["Civil and Environmental Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/30137","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jerome J Connor."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."]},{"key":"dc:creator","label":"Author","values":["Besing, Christa, 1978-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-03-24T18:22:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-03-24T18:22:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil and Environmental Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/30137"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004.","Includes bibliographical references (leaves 52-53)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the procedure for retrofitting a building. This procedure begins with acquiring information about the existing building and its surroundings. The building owner or client then needs to work with the design professional to establish an acceptable performance level, or rehabilitation objective. A rehabilitation method must then be selected that determines how the building should be analyzed. The analysis of the building, including suggested rehabilitation strategies, must then be performed. Once the analysis indicates that the building will perform to its prescribed performance level, the rehabilitation strategies must then be implemented. The thesis ends with a description of two buildings that have recently been retrofitted, or are in the processes of being retrofitted. It gives an overview of the selected rehabilitation strategies and the reasoning behind their selection."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The retrofitting of existing buildings for seismic criteria"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jerome J Connor."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."],"dc:creator":["Besing, Christa, 1978-"],"dc:date.accessioned":["2006-03-24T18:22:57Z"],"dc:date.available":["2006-03-24T18:22:57Z"],"dc:date.issued":["2004"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004.","Includes bibliographical references (leaves 52-53)."],"dc:description.abstract":["This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the procedure for retrofitting a building. This procedure begins with acquiring information about the existing building and its surroundings. The building owner or client then needs to work with the design professional to establish an acceptable performance level, or rehabilitation objective. A rehabilitation method must then be selected that determines how the building should be analyzed. The analysis of the building, including suggested rehabilitation strategies, must then be performed. Once the analysis indicates that the building will perform to its prescribed performance level, the rehabilitation strategies must then be implemented. The thesis ends with a description of two buildings that have recently been retrofitted, or are in the processes of being retrofitted. It gives an overview of the selected rehabilitation strategies and the reasoning behind their selection."],"dc:description.degree":["M.Eng."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/30137"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Civil and Environmental Engineering."],"dc:title":["The retrofitting of existing buildings for seismic criteria"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:18Z"}