Back to results

Massachusetts Institute of Technology

Inverse and transient thermal analysis for rapid hyperthermia therapy planning, delivery and evaluation

Abstract

dc:description.abstract

The efficacy of hyperthermia therapy can be enhanced if a thermal management system is available for therapy planning, delivery and evaluation. The integrated thermal management system is not yet available, though some components of the system have been developed. For example, MIT Hyperthermia Program has developed algorithms for fast forward temperature computation, which include hyperthermia thermal model using Finite Basis Element Method (FBEM) and power model for ultrasound applicators. These components can provide simulated prediction prior to hyperthermia therapy and process evaluation after the therapy. This thesis describes the development of other critical components for the thermal management system: the inverse thermal analysis and the transient thermal analysis. For the inverse thermal analysis, iterative algorithms are used for both the Finite Basis Element Method (FBEM) and Finite Element Method (FEM) to predict the desired power field if the optimal temperature field is given. The simulation results show that both FBEM and FEM predict the optimal power deposition field accurately. FBEM is faster than FEM by an order of magnitude for moderate root mean square (RMS) errors. For the combined inverse thermal analysis that links the optimal temperature field to the control parameters of the energy delivery machine, an inverse algorithm based on source superposition has been developed. Numerical simulations with normalized source array for three simple geometry tumor models have been demonstrated. The simulation results show that the inverse procedure can estimate the optimal control magnitude of each individual source to achieve the optimal temperature field with less than 1⁰C of RMS error.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • He, Jialun, 1966-
Advisor dc:contributor.advisor
  • H. Frederick Bowman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/29627
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/29627

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

He, Jialun, 1966-. Inverse and transient thermal analysis for rapid hyperthermia therapy planning, delivery and evaluation. Massachusetts Institute of Technology, 2003. http://hdl.handle.net/1721.1/29627