Back to results

Massachusetts Institute of Technology

Six-month field monitoring of point-of-use ceramic water filter by using H₂S paper strip most probable number method in San Francisco Libre, Nicaragua

Abstract

dc:description.abstract

Monitoring programs are an essential concomitant to household drinking water treatment. The author implemented a 6-month monitoring program to assess the performance of the Potters for Peace (PFP) water filter in San Francisco Libre, Nicaragua. Both analytical methods and surveys were used to study flow-rate, microbiological removal and user acceptance of 100 PFP filters. Results for the 6-month monitoring by using hydrogen sulfide (H2S) Paper Strip Most Probable Number (H2S MPN) showed that an average of 80.4% of the sample population had less than 2.2 H2S producing colonies per 100 mL after filtration through the PFP filter. Six percent of the visited households had more than 16 CFU/100 mL after filtration. Over the 6 months of the study, the level and pattern of contamination did not change significantly. Filtration rate measurements showed that the average PFP flow-rate was 1.7 L/hrs. Membrane Filtration with mColiBlue24® tests were conducted for half of the sample population in the final month of the study. Total Coliform results showed that 30.6% of the studied families had less than 2.2 CFU/100 mL, and 27% had 0 CFU/100 mL for E-coli when initially present. Approximately 45% of the households had more than 16 CFU/100 mL after filtration for Total Coliform. Yet even so average removal rates for the PFP filter overall were 97.6% for E-coli and 89.3% for Total Coliforms. Users mainly complained about the filter's small capacity (20L), and they requested a ceramic instead of a plastic recipient vessel. Filter breakage was appreciable, since 15% of the filters broke by the end of the study. Recontamination of filtered water due to contaminated receptacles was in 33% of cases. Multiple barrier solutions, such as chlorination after filtration, are recommended for PFP filter users. The H2S MPN method's relevance for long-term monitoring programs in developing countries is evaluated in this report. The use of H2S MPN is recommended for rural areas where there are cost constraints in conjunction with a validation system. Validation of H2S MPN may be given by performing parallel tests with other Standard Methods, such as Membrane Filtration (MF). The report also includes a discussion of lessons learned and recommendations for future monitoring programs of household drinking water systems.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hwang, Rebeca Eun Young, 1979-
Advisor dc:contributor.advisor
  • Susan E. Murcott.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/29556
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/29556

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Hwang, Rebeca Eun Young, 1979-. Six-month field monitoring of point-of-use ceramic water filter by using H₂S paper strip most probable number method in San Francisco Libre, Nicaragua. Massachusetts Institute of Technology, 2003. http://hdl.handle.net/1721.1/29556