{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/28889"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/28889","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Spinal cord regression via collagen entubulation","abstract":"(cont.) days) post-implantation. Histological and immunohistochemical analyses showed severe fibrous and glial scar formation in Groups I and III, less fibrous scarring in Group II and very little scar manifesting in Groups IV and V. A quantitative analysis of myelinated axons in the center of the explants corresponded with the assessment of scar as a physical barrier to competent axon growth. Groups I and III exhibited the least regenerated axons, Groups IV and V the most. The findings also validated the effectiveness of the dorsal barrier in promoting spinal cord regeneration. Overall, the combination of wrap membrane and dorsal barrier (Group V) proved most effective in creating a hospitable environment for regenerative success.","abstract_html":"(cont.) days) post-implantation. Histological and immunohistochemical analyses showed severe fibrous and glial scar formation in Groups I and III, less fibrous scarring in Group II and very little scar manifesting in Groups IV and V. A quantitative analysis of myelinated axons in the center of the explants corresponded with the assessment of scar as a physical barrier to competent axon growth. Groups I and III exhibited the least regenerated axons, Groups IV and V the most. The findings also validated the effectiveness of the dorsal barrier in promoting spinal cord regeneration. Overall, the combination of wrap membrane and dorsal barrier (Group V) proved most effective in creating a hospitable environment for regenerative success.","abstract_has_math":false,"creators":["Matin, Sajjad S. (Sajjad Shaikh), 1979-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.","school":null,"contributors":[],"advisors":["Myron Spector."],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-07-22T22:22:00Z","subjects":["Aeronautics and Astronautics."],"languages":["en_US"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/28889","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Myron Spector."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."]},{"key":"dc:creator","label":"Author","values":["Matin, Sajjad S. (Sajjad Shaikh), 1979-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-27T18:53:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-27T18:53:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aeronautics and Astronautics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/28889"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2004.","Includes bibliographical references (leaves 51-57)."]},{"key":"dc:description.abstract","label":"Abstract","values":["(cont.) days) post-implantation. Histological and immunohistochemical analyses showed severe fibrous and glial scar formation in Groups I and III, less fibrous scarring in Group II and very little scar manifesting in Groups IV and V. A quantitative analysis of myelinated axons in the center of the explants corresponded with the assessment of scar as a physical barrier to competent axon growth. Groups I and III exhibited the least regenerated axons, Groups IV and V the most. The findings also validated the effectiveness of the dorsal barrier in promoting spinal cord regeneration. Overall, the combination of wrap membrane and dorsal barrier (Group V) proved most effective in creating a hospitable environment for regenerative success.","Traumatic injury to the adult mammalian spinal cord results in varying degrees of lost motor and sensory nerve function. Damaged axons of the central nervous system (CNS) exhibit a severely limited regenerative capacity; paralysis induced by severe trauma is generally permanent. Previous studies have attempted to simulate the peripheral nerve environment, where axonal regeneration is spontaneous, through the implantation of peripheral nerve graft tissue, exogenous growth factors or prosthetic devices. Such intervention has demonstrated the ability of central nerve axons to regrow over significant distances and partially restore distal limb function. The current work aims at evaluating the efficacy of two distinct collagen implants towards promoting spinal cord regeneration. The experimental spinal lesion is a 5mm mid-thoracic gap created by transections at T7 and T9 and removal of intermediary cord and peripheral roots. The two implants offered different entubulation schemes; one implant was a thin walled tube composed of Type I bovine collagen, the other a commercially available bilayered membrane composed of Types I and III porcine collagen. Whereas the tube was fitted directly into the spinal lesion, the membrane was wrapped around the cord stumps like a tubular bandage. Five experimental groups defined the current research: Groups I and II received no implant, Groups III and IV were implanted with tubes, and Group V was implanted with the membrane wrap. A secondary aim of the research was to validate the use of a dorsal barrier in further reducing scar infiltration to the wound. This additional collagen membrane was simply draped over the implant (or lesion) of Groups II, IV and V. Mid-thoracic spinal cord sections were explanted from all groups 4 weeks (28"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Spinal cord regression via collagen entubulation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Myron Spector."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."],"dc:creator":["Matin, Sajjad S. (Sajjad Shaikh), 1979-"],"dc:date.accessioned":["2005-09-27T18:53:43Z"],"dc:date.available":["2005-09-27T18:53:43Z"],"dc:date.issued":["2004"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2004.","Includes bibliographical references (leaves 51-57)."],"dc:description.abstract":["(cont.) days) post-implantation. Histological and immunohistochemical analyses showed severe fibrous and glial scar formation in Groups I and III, less fibrous scarring in Group II and very little scar manifesting in Groups IV and V. A quantitative analysis of myelinated axons in the center of the explants corresponded with the assessment of scar as a physical barrier to competent axon growth. Groups I and III exhibited the least regenerated axons, Groups IV and V the most. The findings also validated the effectiveness of the dorsal barrier in promoting spinal cord regeneration. Overall, the combination of wrap membrane and dorsal barrier (Group V) proved most effective in creating a hospitable environment for regenerative success.","Traumatic injury to the adult mammalian spinal cord results in varying degrees of lost motor and sensory nerve function. Damaged axons of the central nervous system (CNS) exhibit a severely limited regenerative capacity; paralysis induced by severe trauma is generally permanent. Previous studies have attempted to simulate the peripheral nerve environment, where axonal regeneration is spontaneous, through the implantation of peripheral nerve graft tissue, exogenous growth factors or prosthetic devices. Such intervention has demonstrated the ability of central nerve axons to regrow over significant distances and partially restore distal limb function. The current work aims at evaluating the efficacy of two distinct collagen implants towards promoting spinal cord regeneration. The experimental spinal lesion is a 5mm mid-thoracic gap created by transections at T7 and T9 and removal of intermediary cord and peripheral roots. The two implants offered different entubulation schemes; one implant was a thin walled tube composed of Type I bovine collagen, the other a commercially available bilayered membrane composed of Types I and III porcine collagen. Whereas the tube was fitted directly into the spinal lesion, the membrane was wrapped around the cord stumps like a tubular bandage. Five experimental groups defined the current research: Groups I and II received no implant, Groups III and IV were implanted with tubes, and Group V was implanted with the membrane wrap. A secondary aim of the research was to validate the use of a dorsal barrier in further reducing scar infiltration to the wound. This additional collagen membrane was simply draped over the implant (or lesion) of Groups II, IV and V. Mid-thoracic spinal cord sections were explanted from all groups 4 weeks (28"],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/28889"],"dc:language.iso":["en_US"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Aeronautics and Astronautics."],"dc:title":["Spinal cord regression via collagen entubulation"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:00Z"}