Back to results

Massachusetts Institute of Technology

The impact of improved materials in poly(vinyl chloride)-based endotracheal tubes

Abstract

dc:description.abstract

Endotracheal tubes (ETs) are used to aid artificial ventilation in millions of medical patients every year and are known to invoke the proliferative phase in the cell linings. The technical objective of this work was to investigate in vitro the interaction between epithelial cells and current poly(vinyl chloride)-based ET materials, as well as some ET samples embedded with materials intended to improve biocompatibility properties of the tubes. Cells were grown in wells with small samples of ETs and proliferation and migration were observed using phase microscopy. ETs appeared to increase cell growth wherever cells came into contact with the material. The cell morphology altered once in contact with the ET sample. Cell growth on and around the ETs with embedded material appeared to slow, but had significant visible changes in cell morphology. The need for continued research in this area of research and development and future steps are addressed. A proposal for starting a company around a safer material for use in endotracheal tubes was developed and showed significant barriers to entry for a small medical device company with a single product. Subsequently, the most appropriate approach for bringing a new ET to the market would be by way of a licensing with an existing manufacturer.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Materials Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Domike, Kristin Rebecca, 1981-
Advisor dc:contributor.advisor
  • Christine Ortiz.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/28871
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28871

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Domike, Kristin Rebecca, 1981-. The impact of improved materials in poly(vinyl chloride)-based endotracheal tubes. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/28871