Study of natural ventilation design by integrating the multi-zone model with CFD simulation

Abstract

dc:description.abstract

Natural ventilation is widely applied in sustainable building design because of its energy saving, indoor air qualify and indoor thermal environment improvement. It is important for architects and engineers to accurately predict the performance of natural ventilation, especially in the building design stage. Unfortunately, there is not any good public tool available to predict the natural ventilation design. The integration of the multi-zone model and the computational fluid dynamics (CFD) simulation provides a way to assess the performance of natural ventilation in whole buildings, as well as the detailed thermal environmental information in some particular space. This work has coupled the multi-zone airflow model with the thermal model. A new program, called MultiVent, has been developed with a web-server that can provide online calculation for the public. The MultiVent program can simultaneously simulate the indoor air temperature and airflow rate with known indoor heat sources for buoyancy dominated, buoyancy-wind combined and wind dominated cases. To properly apply the MultiVent program to the natural ventilation design, two configurations in naturally ventilated buildings should be carefully studied: the atrium and large openings between the zones. A criterion has been set up for dividing the large opening and the connected atrium space into at least two sub-openings and sub-zones. The results of the MultiVent calculation can provide boundary conditions to the CFD simulation for some particular zone. In order to correctly simulate the particular space with CFD, the location and conditions at the integrating surface (boundary surface) have been studied. This work suggested that the simulation zone should include part of the connected atrium space when

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tan, Gang, 1974-
Advisor dc:contributor.advisor
  • Leon Glicksman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28747

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Tan, Gang, 1974-. Study of natural ventilation design by integrating the multi-zone model with CFD simulation. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/28747