Advanced Faraday cage measurements of charge, short-circuit current and open-circuit voltage

Abstract

dc:description.abstract

(cont.) above atmospheric pressure caused both positive current and negative current pulses with the negative pulse larger than the positive pulse. A pressure decrease of more than 10psi below atmospheric pressure also caused both positive current and negative current pulses with the positive current larger than the negative current pulse. Experiments showed that the negative current was generated by the galvanic action between the two dissimilar metals in the triaxial connector connecting the center electrode of the electrode chamber with the electrometer, as water condensed. Positive current could have been produced by the evaporation of moisture from the center electrode of the electrode chamber. Dew point analysis is performed to show that for water to condense on metallic surfaces, it is not necessary to reach the dew point. The calculated dew point temperature is lower than the temperature at which the water condenses upon the electrode surfaces. In the liquid and solid dielectric experiments, we use a patented Faraday cage which is composed of two identical in-line hollow, gold-plated Faraday cup electrodes that enclose the samples which move between them during each measurement under computer control. We conducted charge measurements using various electrometers to rule out the possibility of false instrument readings due to input offset voltage and other experimental effects. One wire mesh style of Faraday cage connected with an electrometer was also used to measure the charge. The liquid dielectrics are distilled water, tap water, Sargasso Sea water ...

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Amin, M. Shahrooz, 1981-
Advisor dc:contributor.advisor
  • Markus Zahn.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/28730
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28730

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Amin, M. Shahrooz, 1981-. Advanced Faraday cage measurements of charge, short-circuit current and open-circuit voltage. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/28730