Back to results

Massachusetts Institute of Technology

A shoe-integrated sensor system for wireless gait analysis and real-time therapeutic feedback

Abstract

dc:description.abstract

Clinical gait analysis currently involves either an expensive analysis in a motion laboratory, using highly accurate, if cumbersome, kinematic systems, or a qualitative analysis with a physician or physical therapist making visual observations. There is a need for a low cost device that falls in between these two methods, and can provide quantitative and repeatable results. In addition, continuous monitoring of gait would be useful for real-time physical rehabilitation. To free patients from the confines of a motion laboratory, this thesis has resulted in a wireless wearable system capable of measuring many parameters relevant to gait analysis. The extensive sensor suite includes three orthogonal accelerometers, and three orthogonal gyroscopes, four force sensors, two bi-directional bend sensors, two dynamic pressure sensors, as well as electric field height sensors. The "GaitShoe" was built to be worn on any shoes, without interfering with gait, and was designed to collect data unobtrusively, in any environment, and over long periods of time. Subject testing of the GaitShoe was carried out on ten healthy subjects with normal gait and five subjects with Parkinson's disease. The calibrated sensor outputs were analyzed, and compared to results obtained simultaneously from The Massachusetts General Hospital Biomotion Lab; the GaitShoe proved highly capable of detecting heel strike and toe off, as well as estimating orientation and position of the subject. A wide variety of features were developed from the calibrated sensor outputs, for use with standard pattern recognition techniques to classify the gait of the subject. The results of the classification demonstrated the ability of the GaitShoe to identify the subjects with

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Morris, Stacy J., 1974-
Advisor dc:contributor.advisor
  • Joseph A. Paradiso.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/28601
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28601

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Morris, Stacy J., 1974-. A shoe-integrated sensor system for wireless gait analysis and real-time therapeutic feedback. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/28601