Back to results

Massachusetts Institute of Technology

Noninvasive assessment of cardiovascular health

Abstract

dc:description.abstract

Cardiovascular health is currently assessed by a collection of hemodynamic parameters many of which can only be measured by invasive methods often requiring hospitalization. A non-invasive approach of evaluating some of these parameters, such as systemic vascular resistance (SVR), maximum left ventricular elasticity (ELV), end diastolic volume (VED), cardiac output and others, has been established. The method has three components: (1) a distributed model of the human cardiovascular system (Ozawa) to generate a solution library that spans the anticipated range of parameter values, (2) a method for establishing the multi-dimensional relationship between features computed from the arterial blood pressure and/or flow traces (e.g., mean arterial pressure, pulse amplitude, mean flow velocity) and the critical hemodynamic parameters, and (3) a parameter estimation method that provides the best fit between measured and computed data. Sensitivity analyses are used to determine the critical parameters that must be allowed to vary, and those that can be assumed to be constant in the model. Given the brachial pressure and velocity profiles (which can be measured non-invasively), this method can estimate SVR with an error of less than 3%, and ELv and VED with less than 10% errors. Measurements on healthy volunteers and patients were conducted in Brigham and Women's Hospital, Boston, MA. Carotid, brachial and radial pressures were measured by tonometry and velocities at corresponding locations were measured by ultrasound. Reasonable agreement is found between the measured pressure and velocity curves and the reconstructed ones. Invasive measurements of hemodynamic parameters are available for two of the patients, which are compared to predictions to evaluate the performance of parameter estimation routines.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xiao, Xinshu
Advisor dc:contributor.advisor
  • Roger D. Kamm.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/28230
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28230

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Xiao, Xinshu. Noninvasive assessment of cardiovascular health. Massachusetts Institute of Technology, 2000. http://hdl.handle.net/1721.1/28230