Back to results

Massachusetts Institute of Technology

A sub-ppb measurement of the mass of cesium for a new determination of the fine-structure constant

Abstract

dc:description.abstract

This thesis describes recent single-ion Penning trap mass spectrometry measurements of the mass of atomic Cesium with a relative uncertainty of 2 x 10-10. This measurement reduces the uncertainty on the mass of Cesium by a factor of 100, and removes this uncertainty as a limitation on the accuracy of a determination of the fine-structure constant alpha via a Cesium photon recoil experiment. Removal of this limit should ultimately allow this value of alpha to have a relative accuracy ~1 ppb, which would be comparable to or even better than the most accurate measurement of alpha currently available. This value of alpha will help shed light on the current ~50 ppb discrepancies between values of alpha measured via different routes. In addition to the mass measurement of Cesium, this thesis also describes related mass measurements of atomic Rubidium and Sodium which reduce the uncertainties on these masses by factors - 100, with a view to possible future photon recoil measurements using these species. The measurements were taken using a new Penning trap mass spectrometer constructed by the author and his colleagues. This new spectrometer followed the general design principles of previous MIT ICR Lab Penning trap mass spectrometers, and incorporated a DC SQUID as an ion detector for the first time. This thesis concludes with a discussion of a passive two-coil system designed for shielding magnetic field gradients. These may prove to be the key enabling technology for a future double Penning trap mass spectrometer.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Physics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bradley, Michael Patrick, 1971-
Advisor dc:contributor.advisor
  • David E. Pritchard.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/28222
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/28222

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Bradley, Michael Patrick, 1971-. A sub-ppb measurement of the mass of cesium for a new determination of the fine-structure constant. Massachusetts Institute of Technology, 2000. http://hdl.handle.net/1721.1/28222