Back to results

Massachusetts Institute of Technology

A micromechanical biosensor with inherently differential readout

Abstract

dc:description.abstract

The ability to detect biomolecules in real-time and without the use of labels has significant benefits for systems biology in terms of cost, time and throughput. Cantilever-based micromechanical sensors detect biomolecular adsorption by means of surface-stress-induced cantilever bending. This technique enables sensitive, scalable and label-free detection of biomolecules in real-time. However, micromachined cantilevers are extremely sensitive to nonspecific chemical effects and temperature changes. This thesis explores a micromechanical sensor that suppresses disturbances by generating an inherently differential signal with respect to a reference surface. The thesis covers the design, fabrication, characterization of the sensor, and its application to protein detection using aptamers; receptor molecules produced in vitro. The sensor is composed of two adjacent cantilevers that form a sensor-reference pair, whereby only the sensing surface is activated with receptor molecules that are specific to the ligand to be detected. The relative, or differential bending between the two cantilevers is directly measured using interferometry. Through direct differential detection, disturbances affecting both cantilevers are suppressed at the measurement level. This eliminates the need for separate detection of each cantilever's motion and off-line processing of the individual signals. At high frequencies, the resolution of the sensor is only limited by its sub-angstrom-level thermomechanical noise. At lower frequencies (frequencies of interest), the resolution is limited by 1/f-type noise which can be reduced by as much as an order of magnitude by direct differential detection, enabling clear observation of receptor-ligand binding

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Savran, Cagri Abdullah, 1976-
Advisor dc:contributor.advisor
  • Scott R. Manalis.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/17944
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/17944

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Savran, Cagri Abdullah, 1976-. A micromechanical biosensor with inherently differential readout. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/17944