{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/17585"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/17585","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A six-degree of freedom flexural positioning stage","abstract":"A novel, low-cost positioning stage was constructed using a six-axis compliant mechanism driven by three two-axis electromagnetic actuators. The mechanism's monolithic, planar geometry is easily fabricated with low-cost manufacturing processes (such as waterjet machining). The manipulator tolerates ±1 mm actuator misalignment with less than 0.1% full-scale position error. Measurements over a 100x100x100 nm3 work volume displayed resolution better than the sensing capability, 5nm, and open-loop linearity errors less than 0.005% of the full-scale range (100 [mu]m). Measurements over a 100x100x100 [mu]m3 work volume exhibited linearity errors less than 0.20% full-scale. The mechanism's equilateral symmetry and planar geometry restricted thermal drift rates at start-up to 23nm and 4 [mu]tradians over 30 minutes and 0.1°C temperature change. The manipulator, built for $ 2000 (excluding electronics), was successfully tested in a fiber optic alignment application.","abstract_html":"A novel, low-cost positioning stage was constructed using a six-axis compliant mechanism driven by three two-axis electromagnetic actuators. The mechanism&#x27;s monolithic, planar geometry is easily fabricated with low-cost manufacturing processes (such as waterjet machining). The manipulator tolerates ±1 mm actuator misalignment with less than 0.1% full-scale position error. Measurements over a 100x100x100 nm3 work volume displayed resolution better than the sensing capability, 5nm, and open-loop linearity errors less than 0.005% of the full-scale range (100 [mu]m). Measurements over a 100x100x100 [mu]m3 work volume exhibited linearity errors less than 0.20% full-scale. The mechanism&#x27;s equilateral symmetry and planar geometry restricted thermal drift rates at start-up to 23nm and 4 [mu]tradians over 30 minutes and 0.1°C temperature change. The manipulator, built for $ 2000 (excluding electronics), was successfully tested in a fiber optic alignment application.","abstract_has_math":false,"creators":["Anderson, Gordon A. B. (Gordon Alexander Brewster), 1977-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Martin Culpepper."],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003","date_published":"2003","updated_at":"2026-07-22T22:21:54Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/17585","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Martin Culpepper."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Anderson, Gordon A. B. (Gordon Alexander Brewster), 1977-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-06-02T16:17:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-06-02T16:17:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2003"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/17585"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2003.","Includes bibliographical references (p. 134-136)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A novel, low-cost positioning stage was constructed using a six-axis compliant mechanism driven by three two-axis electromagnetic actuators. The mechanism's monolithic, planar geometry is easily fabricated with low-cost manufacturing processes (such as waterjet machining). The manipulator tolerates ±1 mm actuator misalignment with less than 0.1% full-scale position error. Measurements over a 100x100x100 nm3 work volume displayed resolution better than the sensing capability, 5nm, and open-loop linearity errors less than 0.005% of the full-scale range (100 [mu]m). Measurements over a 100x100x100 [mu]m3 work volume exhibited linearity errors less than 0.20% full-scale. The mechanism's equilateral symmetry and planar geometry restricted thermal drift rates at start-up to 23nm and 4 [mu]tradians over 30 minutes and 0.1°C temperature change. The manipulator, built for $ 2000 (excluding electronics), was successfully tested in a fiber optic alignment application."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A six-degree of freedom flexural positioning stage"]}]}],"canonical_facts":{"dc:contributor.advisor":["Martin Culpepper."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Anderson, Gordon A. B. (Gordon Alexander Brewster), 1977-"],"dc:date.accessioned":["2005-06-02T16:17:00Z"],"dc:date.available":["2005-06-02T16:17:00Z"],"dc:date.issued":["2003"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2003.","Includes bibliographical references (p. 134-136)."],"dc:description.abstract":["A novel, low-cost positioning stage was constructed using a six-axis compliant mechanism driven by three two-axis electromagnetic actuators. The mechanism's monolithic, planar geometry is easily fabricated with low-cost manufacturing processes (such as waterjet machining). The manipulator tolerates ±1 mm actuator misalignment with less than 0.1% full-scale position error. Measurements over a 100x100x100 nm3 work volume displayed resolution better than the sensing capability, 5nm, and open-loop linearity errors less than 0.005% of the full-scale range (100 [mu]m). Measurements over a 100x100x100 [mu]m3 work volume exhibited linearity errors less than 0.20% full-scale. The mechanism's equilateral symmetry and planar geometry restricted thermal drift rates at start-up to 23nm and 4 [mu]tradians over 30 minutes and 0.1°C temperature change. The manipulator, built for $ 2000 (excluding electronics), was successfully tested in a fiber optic alignment application."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/17585"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["A six-degree of freedom flexural positioning stage"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:54Z"}