{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/16994"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/16994","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Studies on the ion-droplet mixed regime in colloid thrusters","abstract":"Colloid thrusters working with mixtures of ions and droplets are gradually becoming an alternative technology for space micro-propulsion needs in missions requiring high position controllability, compactness and low power consumption. The mechanics of the colloid thruster emission process are discussed through a theoretical review of its general properties and by means of experimental characterization. Droplets are the most energetic particles in the beam, while ions are emitted with energies that overlap those of the droplets but extend down a few hundreds of volts in comparison. A small fraction of the ion current is emitted from the jet breakup region with considerably lower energies. This energy variety transforms the optical hardware elements into energy filters by taking advantage of the chromatic aberration property of electrostatic lenses. The relatively wide ion energy distribution is conceptually explained as a result of emission from different locations in the cone-jet structure where the normal electric field is most intense and where the convective current produces drastic changes in the local potential. The energy spread of purely ionic emission from EMI-BF4 is measured and is found to be of the order of a few tens of volts. A high-speed electron multiplier detector is used for the first time to analyze the ion component emitted directly from electrospray sources. Ion identification is performed and is found that the most probable degree of solvation is n = 5.1 for (CH3NO)nNa+ ions in formamide doped with NaI for a conductivity of 2.15 siemens per meter.","abstract_html":"Colloid thrusters working with mixtures of ions and droplets are gradually becoming an alternative technology for space micro-propulsion needs in missions requiring high position controllability, compactness and low power consumption. The mechanics of the colloid thruster emission process are discussed through a theoretical review of its general properties and by means of experimental characterization. Droplets are the most energetic particles in the beam, while ions are emitted with energies that overlap those of the droplets but extend down a few hundreds of volts in comparison. A small fraction of the ion current is emitted from the jet breakup region with considerably lower energies. This energy variety transforms the optical hardware elements into energy filters by taking advantage of the chromatic aberration property of electrostatic lenses. The relatively wide ion energy distribution is conceptually explained as a result of emission from different locations in the cone-jet structure where the normal electric field is most intense and where the convective current produces drastic changes in the local potential. The energy spread of purely ionic emission from EMI-BF4 is measured and is found to be of the order of a few tens of volts. A high-speed electron multiplier detector is used for the first time to analyze the ion component emitted directly from electrospray sources. Ion identification is performed and is found that the most probable degree of solvation is n = 5.1 for (CH3NO)nNa+ ions in formamide doped with NaI for a conductivity of 2.15 siemens per meter.","abstract_has_math":false,"creators":["Lozano-Tovar, Paulo César, 1970-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.","school":null,"contributors":[],"advisors":["Manuel Martínez-Sánchez."],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003","date_published":"2003","updated_at":"2026-07-22T22:21:40Z","subjects":["Aeronautics and Astronautics."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/16994","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Manuel Martínez-Sánchez."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."]},{"key":"dc:creator","label":"Author","values":["Lozano-Tovar, Paulo César, 1970-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-05-19T15:34:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-05-19T15:34:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2003"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aeronautics and Astronautics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/16994"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2003.","Page 222 blank.","Includes bibliographical references (p. 217-221).","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections."]},{"key":"dc:description.abstract","label":"Abstract","values":["Colloid thrusters working with mixtures of ions and droplets are gradually becoming an alternative technology for space micro-propulsion needs in missions requiring high position controllability, compactness and low power consumption. The mechanics of the colloid thruster emission process are discussed through a theoretical review of its general properties and by means of experimental characterization. Droplets are the most energetic particles in the beam, while ions are emitted with energies that overlap those of the droplets but extend down a few hundreds of volts in comparison. A small fraction of the ion current is emitted from the jet breakup region with considerably lower energies. This energy variety transforms the optical hardware elements into energy filters by taking advantage of the chromatic aberration property of electrostatic lenses. The relatively wide ion energy distribution is conceptually explained as a result of emission from different locations in the cone-jet structure where the normal electric field is most intense and where the convective current produces drastic changes in the local potential. The energy spread of purely ionic emission from EMI-BF4 is measured and is found to be of the order of a few tens of volts. A high-speed electron multiplier detector is used for the first time to analyze the ion component emitted directly from electrospray sources. Ion identification is performed and is found that the most probable degree of solvation is n = 5.1 for (CH3NO)nNa+ ions in formamide doped with NaI for a conductivity of 2.15 siemens per meter.","(cont.) Two ions are observed for the ionic liquid EMI-BF4: EMI+ and (EMI-BF4)EMI+. It is found that these ions are emitted with a small energy differential. The use of 5 micron ID capillary emitters, working with flow rates close to 20 pico-liters per second, is successfully achieved. Under such conditions, highly charged droplets with specific charges in excess of 10 coulombs per gram are obtained, representing the highest charge state obtained so far in experiments of this kind. The applicability of colloid thrusters for space propulsion is discussed in terms of performance parameters in the ion-droplet mixed regime, along with other practical considerations, such as the problem of beam neutralization."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Studies on the ion-droplet mixed regime in colloid thrusters"]}]}],"canonical_facts":{"dc:contributor.advisor":["Manuel Martínez-Sánchez."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."],"dc:creator":["Lozano-Tovar, Paulo César, 1970-"],"dc:date.accessioned":["2005-05-19T15:34:42Z"],"dc:date.available":["2005-05-19T15:34:42Z"],"dc:date.issued":["2003"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2003.","Page 222 blank.","Includes bibliographical references (p. 217-221).","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections."],"dc:description.abstract":["Colloid thrusters working with mixtures of ions and droplets are gradually becoming an alternative technology for space micro-propulsion needs in missions requiring high position controllability, compactness and low power consumption. The mechanics of the colloid thruster emission process are discussed through a theoretical review of its general properties and by means of experimental characterization. Droplets are the most energetic particles in the beam, while ions are emitted with energies that overlap those of the droplets but extend down a few hundreds of volts in comparison. A small fraction of the ion current is emitted from the jet breakup region with considerably lower energies. This energy variety transforms the optical hardware elements into energy filters by taking advantage of the chromatic aberration property of electrostatic lenses. The relatively wide ion energy distribution is conceptually explained as a result of emission from different locations in the cone-jet structure where the normal electric field is most intense and where the convective current produces drastic changes in the local potential. The energy spread of purely ionic emission from EMI-BF4 is measured and is found to be of the order of a few tens of volts. A high-speed electron multiplier detector is used for the first time to analyze the ion component emitted directly from electrospray sources. Ion identification is performed and is found that the most probable degree of solvation is n = 5.1 for (CH3NO)nNa+ ions in formamide doped with NaI for a conductivity of 2.15 siemens per meter.","(cont.) Two ions are observed for the ionic liquid EMI-BF4: EMI+ and (EMI-BF4)EMI+. It is found that these ions are emitted with a small energy differential. The use of 5 micron ID capillary emitters, working with flow rates close to 20 pico-liters per second, is successfully achieved. Under such conditions, highly charged droplets with specific charges in excess of 10 coulombs per gram are obtained, representing the highest charge state obtained so far in experiments of this kind. The applicability of colloid thrusters for space propulsion is discussed in terms of performance parameters in the ion-droplet mixed regime, along with other practical considerations, such as the problem of beam neutralization."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/16994"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Aeronautics and Astronautics."],"dc:title":["Studies on the ion-droplet mixed regime in colloid thrusters"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:40Z"}