Massachusetts Institute of Technology
A transition radiation detector and gas supply system for AMS
Abstract
dc:description.abstractAlpha Magnetic Spectrometer is an experiment that will be on the International Space Station for three years. It will look for anti-matter and dark matter. Supersymmetric dark matter could produce an excess in the 10-300GeV positron spectrum. A 10-6 separation of positrons from the more abundant protons is planned for this signal. A TRD (Transition Radiation Detector) has been designed to achieve these physics goals. Besides the radiator, the TRD is a gaseous detector that needs a gas system providing signal stability to 3%. The design, and construction of the TRD gas supply system is described with emphasis on the electronics control.
Degree
thesis:*- Department dc:contributor.department
- Massachusetts Institute of Technology. Dept. of Physics.
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Demirköz, Bilge Melahat, 1980-
- Advisor dc:contributor.advisor
-
- Ulrich J. Becker.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1721.1/16645
- OAI identifier oai:identifier
- oai:dspace.mit.edu:1721.1/16645