Back to results

Massachusetts Institute of Technology

Carbon Capture Efficiency in Natural Gas Combined Cycle Power Plants: Analyzing the Effects of Variable Load Operations

Abstract

dc:description.abstract

Natural gas power generation retrofitted with carbon capture technology is poised to play a crucial role in ensuring energy reliability amidst the transition to variable renewable energy resources. While natural gas generation is used primarily for baseload power, it is expected to transition towards an intermittent power generator, serving as a load-following resource during periods of low renewable energy availability. It will be critical to understand how start-up, shutdown, and load-following behavior may impact system performance and influence future grid design. This thesis performs a comprehensive literature review to establish context on various techniques of carbon capture technology. Post-combustion carbon capture, specifically absorption-based technology, remains the preferred candidate for retrofitting natural gas plants due to its technical maturity, scalability, relatively high capture efficiencies, and ease of retrofitting. The literature highlights that absorption-based carbon capture units exhibit degraded performance during non-steady-state operating conditions. Specifically, cold start-ups result in lower capture efficiencies and higher heat rates, although hot start-ups incur significantly less performance reduction. The literature review findings are integrated into GenX, a grid optimization tool, to evaluate natural gas combined cycle power plants equipped with carbon capture technology. The modified optimization models are run using the ISO New England grid system, and results suggest that incorporating advanced start-up penalties for natural gas plants reduces operational flexibility in an emissions-constrained environment. As capture efficiencies decrease and heat rates increase during start-ups, utilizing natural gas plants becomes more expensive due to the additional emissions and reduced thermal efficiency. Comparing models with different levels of performance degradation during start-up suggests that installing less gas capacity could be optimal, with those units operating at higher capacity factors to mitigate start-up penalties. Under modest emissions constraints, natural gas units may be operated continuously even during periods of renewable energy surplus. Harsher start-up penalties applied to natural gas plants likely increase the incremental value of alternative energy technologies, although natural gas retains a critical role in the energy mix.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
System Design and Management Program.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Knight, Caleb M.
Advisors dc:contributor.advisor
  • Rhodes, Donna H.
  • Macdonald, Ruaridh

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/157211
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/157211

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Knight, Caleb M.. Carbon Capture Efficiency in Natural Gas Combined Cycle Power Plants: Analyzing the Effects of Variable Load Operations. Massachusetts Institute of Technology, 2024. https://hdl.handle.net/1721.1/157211