{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/156587"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/156587","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Experimental Validation of Indirect Liquid Cooling Computational Thermal Modeling","abstract":"Indirect dry-interface liquid cooling for electronics offers a modular and lightweight approach to thermal management. As part of development for the Navy’s integrated Power and Energy Corridor (NiPEC), multiple computational thermal analyses of this cooling method have been conducted but not yet tested against experimental results. NiPEC involves the deployment of converter units referred to as integrated Power Electronics Building Blocks (iPEBBs), which experience heat generation from four rows of MOSFET switches and a transformer. The goal of thermal simulations is to predict the liquid flow rate through a cold plate given a heat flux which will keep the iPEBBs below 100◦C. Experimental data on indirect liquid cooling of a layered substrate was collected with varied power, temperatures and flow rates. The data was verified through a STAR-CCM+ CFD simulation by David Hernandez, then used as a training and test set for a physics-informed neural net- work (PINN) model by Aniruddha Bora. The PINNs simulations were shown to improve in consistency and accuracy when trained on data gathered in the experimental trials. The collected experimental data set is available to the public for training and testing computational models.","abstract_html":"Indirect dry-interface liquid cooling for electronics offers a modular and lightweight approach to thermal management. As part of development for the Navy’s integrated Power and Energy Corridor (NiPEC), multiple computational thermal analyses of this cooling method have been conducted but not yet tested against experimental results. NiPEC involves the deployment of converter units referred to as integrated Power Electronics Building Blocks (iPEBBs), which experience heat generation from four rows of MOSFET switches and a transformer. The goal of thermal simulations is to predict the liquid flow rate through a cold plate given a heat flux which will keep the iPEBBs below 100◦C. Experimental data on indirect liquid cooling of a layered substrate was collected with varied power, temperatures and flow rates. The data was verified through a STAR-CCM+ CFD simulation by David Hernandez, then used as a training and test set for a physics-informed neural net- work (PINN) model by Aniruddha Bora. The PINNs simulations were shown to improve in consistency and accuracy when trained on data gathered in the experimental trials. The collected experimental data set is available to the public for training and testing computational models.","abstract_has_math":false,"creators":["Alvarez, Isabel K."],"institution":"Massachusetts Institute of Technology","degree_name":"Bachelor","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Mechanical Engineering","school":null,"contributors":[],"advisors":["Chalfant, Julie","Triantafyllou, Michael"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-05","date_published":"2024-05","updated_at":"2026-07-22T22:22:00Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/156587","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chalfant, Julie","Triantafyllou, Michael"]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Alvarez, Isabel K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-09-03T21:09:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-03T21:09:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-05"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Bachelor","Bachelor of Science in Mechanical and Ocean Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/156587"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Indirect dry-interface liquid cooling for electronics offers a modular and lightweight approach to thermal management. As part of development for the Navy’s integrated Power and Energy Corridor (NiPEC), multiple computational thermal analyses of this cooling method have been conducted but not yet tested against experimental results. NiPEC involves the deployment of converter units referred to as integrated Power Electronics Building Blocks (iPEBBs), which experience heat generation from four rows of MOSFET switches and a transformer. The goal of thermal simulations is to predict the liquid flow rate through a cold plate given a heat flux which will keep the iPEBBs below 100◦C. Experimental data on indirect liquid cooling of a layered substrate was collected with varied power, temperatures and flow rates. The data was verified through a STAR-CCM+ CFD simulation by David Hernandez, then used as a training and test set for a physics-informed neural net- work (PINN) model by Aniruddha Bora. The PINNs simulations were shown to improve in consistency and accuracy when trained on data gathered in the experimental trials. The collected experimental data set is available to the public for training and testing computational models."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Experimental Validation of Indirect Liquid Cooling Computational Thermal Modeling"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chalfant, Julie","Triantafyllou, Michael"],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Mechanical Engineering"],"dc:creator":["Alvarez, Isabel K."],"dc:date.accessioned":["2024-09-03T21:09:39Z"],"dc:date.available":["2024-09-03T21:09:39Z"],"dc:date.issued":["2024-05"],"dc:description.abstract":["Indirect dry-interface liquid cooling for electronics offers a modular and lightweight approach to thermal management. As part of development for the Navy’s integrated Power and Energy Corridor (NiPEC), multiple computational thermal analyses of this cooling method have been conducted but not yet tested against experimental results. NiPEC involves the deployment of converter units referred to as integrated Power Electronics Building Blocks (iPEBBs), which experience heat generation from four rows of MOSFET switches and a transformer. The goal of thermal simulations is to predict the liquid flow rate through a cold plate given a heat flux which will keep the iPEBBs below 100◦C. Experimental data on indirect liquid cooling of a layered substrate was collected with varied power, temperatures and flow rates. The data was verified through a STAR-CCM+ CFD simulation by David Hernandez, then used as a training and test set for a physics-informed neural net- work (PINN) model by Aniruddha Bora. The PINNs simulations were shown to improve in consistency and accuracy when trained on data gathered in the experimental trials. The collected experimental data set is available to the public for training and testing computational models."],"dc:description.degree":["S.B."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/156587"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Experimental Validation of Indirect Liquid Cooling Computational Thermal Modeling"],"dc:type":["Thesis"],"thesis:degree_name":["Bachelor","Bachelor of Science in Mechanical and Ocean Engineering"]},"updated_at":"2026-07-22T22:22:00Z"}