{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/156321"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/156321","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A Compact Hydraulic Head Auto-Regulating Module (CHARM) for Long-Term Constant Gravity-Driven Flow Microfluidics","abstract":"Gravity-driven flow is a simple microfluidic flow initiation and maintenance mechanism that requires no external power sources and low expertise to use. However, the driving forces created by hydraulic head differences gradually decrease during operation, resulting in unwanted decreased flow rates in many microfluidic applications. The existing methods to maintain a constant flow for gravity-driven mechanisms either require additional bulky control equipment, involve complex fabrication or operation, or introduce interfaces that lack robustness. To solve those problems, a compact hydraulic head auto-regulating module (CHARM) was designed and tested in this thesis. The module was able to maintain the liquid level at the microfluidic inlet port within a small fluctuation range without human intervention for a long operation time. The design’s compactness and its compatibility with the standard 96 well plates enable high-throughput operations, and the chosen material’s bio-compatibility allows the devices’ use on cell culture related applications.","abstract_html":"Gravity-driven flow is a simple microfluidic flow initiation and maintenance mechanism that requires no external power sources and low expertise to use. However, the driving forces created by hydraulic head differences gradually decrease during operation, resulting in unwanted decreased flow rates in many microfluidic applications. The existing methods to maintain a constant flow for gravity-driven mechanisms either require additional bulky control equipment, involve complex fabrication or operation, or introduce interfaces that lack robustness. To solve those problems, a compact hydraulic head auto-regulating module (CHARM) was designed and tested in this thesis. The module was able to maintain the liquid level at the microfluidic inlet port within a small fluctuation range without human intervention for a long operation time. The design’s compactness and its compatibility with the standard 96 well plates enable high-throughput operations, and the chosen material’s bio-compatibility allows the devices’ use on cell culture related applications.","abstract_has_math":false,"creators":["Xue, Fan"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science","school":null,"contributors":[],"advisors":["Voldman, Joel"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-05","date_published":"2024-05","updated_at":"2026-07-22T22:22:31Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/156321","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Voldman, Joel"]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science"]},{"key":"dc:creator","label":"Author","values":["Xue, Fan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-21T18:56:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-21T18:56:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-05"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Science in Electrical Engineering and Computer Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/156321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Gravity-driven flow is a simple microfluidic flow initiation and maintenance mechanism that requires no external power sources and low expertise to use. However, the driving forces created by hydraulic head differences gradually decrease during operation, resulting in unwanted decreased flow rates in many microfluidic applications. The existing methods to maintain a constant flow for gravity-driven mechanisms either require additional bulky control equipment, involve complex fabrication or operation, or introduce interfaces that lack robustness. To solve those problems, a compact hydraulic head auto-regulating module (CHARM) was designed and tested in this thesis. The module was able to maintain the liquid level at the microfluidic inlet port within a small fluctuation range without human intervention for a long operation time. The design’s compactness and its compatibility with the standard 96 well plates enable high-throughput operations, and the chosen material’s bio-compatibility allows the devices’ use on cell culture related applications."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["A Compact Hydraulic Head Auto-Regulating Module (CHARM) for Long-Term Constant Gravity-Driven Flow Microfluidics"]}]}],"canonical_facts":{"dc:contributor.advisor":["Voldman, Joel"],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science"],"dc:creator":["Xue, Fan"],"dc:date.accessioned":["2024-08-21T18:56:38Z"],"dc:date.available":["2024-08-21T18:56:38Z"],"dc:date.issued":["2024-05"],"dc:description.abstract":["Gravity-driven flow is a simple microfluidic flow initiation and maintenance mechanism that requires no external power sources and low expertise to use. However, the driving forces created by hydraulic head differences gradually decrease during operation, resulting in unwanted decreased flow rates in many microfluidic applications. The existing methods to maintain a constant flow for gravity-driven mechanisms either require additional bulky control equipment, involve complex fabrication or operation, or introduce interfaces that lack robustness. To solve those problems, a compact hydraulic head auto-regulating module (CHARM) was designed and tested in this thesis. The module was able to maintain the liquid level at the microfluidic inlet port within a small fluctuation range without human intervention for a long operation time. The design’s compactness and its compatibility with the standard 96 well plates enable high-throughput operations, and the chosen material’s bio-compatibility allows the devices’ use on cell culture related applications."],"dc:description.degree":["S.M."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/156321"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["A Compact Hydraulic Head Auto-Regulating Module (CHARM) for Long-Term Constant Gravity-Driven Flow Microfluidics"],"dc:type":["Thesis"],"thesis:degree_name":["Master","Master of Science in Electrical Engineering and Computer Science"]},"updated_at":"2026-07-22T22:22:31Z"}