Shutdown Dose Rate Modeling for Radiation Requirements Development and Design Trend Analysis in the ARC Fusion Device

Abstract

dc:description.abstract

To achieve commercial viability, Commonwealth Fusion System’s ARC device must maximize its availability to produce power, thus demanding a rapid maintenance process to replace radiation-damaged components. Designing robotic systems to operate in this radiation environment requires understanding the expected radiation levels and how design decisions impact those levels. This thesis uses the Rigorous Two-Step (R2S) methodology to scope the radiation environment and provide data for those design trade-offs that must be considered in future ARC design iterations. The first trend is Vanadium’s lower dose rate than Eurofer as a Vacuum Vessel and Blanket Tank material in all configurations, making it the preferred candidate from a radiation perspective. Second, the model indicates that the choice in Blanket Tank material contributes non-trivially to the maintenance radiation environment. Third, the trends demonstrate minimal additional reduction in radiation levels from delaying the start of maintenance beyond 14 days after fusion ceases. The final trend shows the reduction in the radiation field from the removal of the Blanket Tank with the Vacuum Vessel warrants future study. Finally, this thesis incorporates historical nuclear robotics experience to establish an iterative process by which to develop robotic radiation requirements and assess maintenance decision effects on ARC-level optimality.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Murphy, Daniel T.
Advisors dc:contributor.advisor
  • Whyte, Dennis G.
  • Roemer, Thomas

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/156046
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/156046

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Murphy, Daniel T.. Shutdown Dose Rate Modeling for Radiation Requirements Development and Design Trend Analysis in the ARC Fusion Device. Massachusetts Institute of Technology, 2024. https://hdl.handle.net/1721.1/156046