Back to results

Massachusetts Institute of Technology

Neutron Resonance Transmission Analysis of Nuclear Material Using a Portable D-T Neutron Generator

Abstract

dc:description.abstract

The accurate identification and quantification of nuclear material is important for nuclear security, nonproliferation, and safeguards missions. Existing techniques have limitations in terms of their isotopic specificity, isotopic range, and their capacity to analyze thick or shielded targets. Neutron Resonance Transmission Analysis (NRTA) is an active neutron interrogation technique that addresses these challenges by offer- ing isotope-specificity, applicability to a wide range of mid- and high-Z isotopes, and the ability to assay targets shielded by high-Z material. However, the dependence of NRTA on large beamline facilities to generate high neutron flux and achieve excellent system resolution has prevented the technique from being used for on-site applica- tions. To overcome this limitation, this thesis presents a portable NRTA system design that utilizes a commercial-off-the-shelf D-T neutron generator. The portable system, comprising a neutron source and neutron detector assembly, each weighing less than 40 kg, enables easy transport and setup for on-site applications. The system is capable of achieving sufficient flux and resolution to identify neutron resonances up to approximately 60 eV in under an hour, making it suitable for analyzing high-Z targets with thicknesses of several centimeters and with up to several millimeters of low-Z shielding. The feasibility of the portable NRTA system for a number of nonpro- liferation and safeguards applications was evaluated by assaying various uranium and plutonium targets. The system successfully assayed both depleted and high enriched uranium and reactor-grade plutonium targets, accurately determining the enrichment and fissile mass content as validated by chemical analysis. The system was also able to assay combinations of thorium and uranium metal of varying enrichment, as well as small quantities of U-233 oxide under high passive gamma backgrounds to accuracies under a gram. These results highlight the potential viability of using a portable NRTA system to support nuclear nonproliferation missions that require the non-destructive assay of a diverse range of nuclear materials, including advanced reactor safeguards for the thorium fuel cycle and the confirmation of special nuclear material for arms control treaty verification.

Degree

thesis:*
Name thesis:degree_name
Doctoral
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Klein, Ethan Avram
Advisor dc:contributor.advisor
  • Danagoulian, Areg

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/152884
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/152884

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Klein, Ethan Avram. Neutron Resonance Transmission Analysis of Nuclear Material Using a Portable D-T Neutron Generator. Massachusetts Institute of Technology, 2023. https://hdl.handle.net/1721.1/152884