Abstract

dc:description.abstract

Over the past decade, work in the medical field has been geared towards the development of ultrasonic systems for medical diagnostic imaging applications. Compared to other imaging modalities, patient contact is a significant source of variability unique to ultrasound. Contact sensitive applications such as remote patient/neonatal monitoring, tracking wound healing, and imaging of sensitive skin areas can significantly benefit from a non-contact ultrasound system. Laser ultrasound (LUS) imaging offers potential advancements over conventional ultrasound, especially in achieving highresolution imaging of tissue structures and the elimination of liquid coupling mediums and probe-to-body contact. The thesis presents an innovative approach to enhance the performance of LUS signals in human tissue by utilizing hydrogels, hydrophilic polymeric materials known for high-water content and biocompatibility, as a surface treatment layer for ultrasound detection and generation. The system integrates and synchronizes linear stage automation, transducer acoustic wave generation, laser doppler vibrometry (LDV), and LabView integration. High speed data acquisition (DAQ) through a dedicated Pico Technology setup streams digitized data directly to the host PC. LDV measurements highlighted the crucial role of bead concentration within hydrogels. Velocity amplitude measurements reflected an inverse relationship with increasing bead concentrations, peaking at approximately 700 mm/s. However, higher bead concentrations yielded better data accuracy and reduced noise, suggesting an optimal range for bead concentration.A comparison of noise ranges across different hydrogel bead concentrations highlighted improved data quality and precision for concentrations exceeding 0.015 g/mL. Furthermore, laser-based measurements indicated that hydrogel with a bead concentration of 0.02 g/mL provided consistent and enhanced signal amplitude. The findings present a pivotal step towards optimizing LUS for clinical applications, opening new doors in medical imaging and diagnostics.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Caraballo-Justiniano, Eugenio
Advisor dc:contributor.advisor
  • Anthony, Brian W.

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/152810
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/152810

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Caraballo-Justiniano, Eugenio. Hydrogel Design Optimization for Measuring Ultrasound Using Laser Doppler Vibrometry. Massachusetts Institute of Technology, 2023. https://hdl.handle.net/1721.1/152810