Back to results

Massachusetts Institute of Technology

Evaluation of Ion Transfer Capillary Geometry on Sensitivity of a Desorption Electrospray Ionization and Mass Spectrometry System

Abstract

dc:description.abstract

This research examines the effect of ion transfer capillary geometry on the sensitivity of the Desorption Electrospray Ionization – Mass Spectrometry (DESI-MS) process. Previous work has shown that heating the ion transfer capillary to 450˚C will improve the resolution of images taken by the DESI-MS owing to increased ion desolvation. This thesis studies how changing the inner diameter and cross-sectional profile of the capillary can improve ion desolvation by increased heat transfer to the center of the flow. Increasing heat transfer efficiency can obviate such high temperatures and will increase flexibility in the design of the capillary heater. The setup of this experiment involved making modifications to existing components to allow for rapid testing of many ion transfer capillary geometries. Mass spectrum data for sample sections of pig liver were collected, as these biological samples are acceptably homogenous with a known mass-to-charge (m/z) ratio of 885. Signal intensity within the 880- 890 m/z range is analyzed to reveal the impact of capillary geometry. Sources of variation, such as within-sample variation and sample-to-sample variation, are characterized to reveal the true impact of the variables. The results show that decreasing max particle distance from a wall can increase the sensitivity of the ion flow to heating. The best capillary cross-section provides nearly a 4x increase in sensitivity when compared to a circular capillary with a similar flow area. Pursuing these capillary designs will improve not only sample resolution and imaging time but also the client satisfaction of the Waters DESI- MS system.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vinakollu, Nagashumrith Venkata
Advisor dc:contributor.advisor
  • Hardt, David E.

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/152612
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/152612

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Vinakollu, Nagashumrith Venkata. Evaluation of Ion Transfer Capillary Geometry on Sensitivity of a Desorption Electrospray Ionization and Mass Spectrometry System. Massachusetts Institute of Technology, 2021. https://hdl.handle.net/1721.1/152612