{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/151536"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/151536","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Unsupervised Representation Learning from Intravascular Ultrasound Videos","abstract":"Vascular diseases such as atherosclerosis are a leading cause of mortality and morbidity worldwide. Intravascular Ultrasound (IVUS) is an imaging technology that has the distinctive ability to offer real-time endovascular information of the coronary vasculature. However, its low signal-to-noise ratio, low data availability, and numerous artifacts make it challenging to use both for humans and automated methods. This work explores the use of representation learning and de-noising techniques to address these challenges and aid in the diagnosis of vascular diseases. We test our methods on the task of stent malapposition detection, where naive approaches fail discouragingly. We improve the naive baseline accuracy by 16%. In addition, we develop a deep learning approach for real-time stabilization of the IVUS videos, which performs registration 20-fold faster than the classical ANTs approach. Our results demonstrate the importance of incorporating domain knowledge in performance improvement while still indicating the limitations of current systems for achieving clinically ready performance.","abstract_html":"Vascular diseases such as atherosclerosis are a leading cause of mortality and morbidity worldwide. Intravascular Ultrasound (IVUS) is an imaging technology that has the distinctive ability to offer real-time endovascular information of the coronary vasculature. However, its low signal-to-noise ratio, low data availability, and numerous artifacts make it challenging to use both for humans and automated methods. This work explores the use of representation learning and de-noising techniques to address these challenges and aid in the diagnosis of vascular diseases. We test our methods on the task of stent malapposition detection, where naive approaches fail discouragingly. We improve the naive baseline accuracy by 16%. In addition, we develop a deep learning approach for real-time stabilization of the IVUS videos, which performs registration 20-fold faster than the classical ANTs approach. Our results demonstrate the importance of incorporating domain knowledge in performance improvement while still indicating the limitations of current systems for achieving clinically ready performance.","abstract_has_math":false,"creators":["Jain, Lay"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science","school":null,"contributors":[],"advisors":["Golland, Polina"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-06","date_published":"2023-06","updated_at":"2026-07-22T22:22:22Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/151536","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Golland, Polina"]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science"]},{"key":"dc:creator","label":"Author","values":["Jain, Lay"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-07-31T19:47:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-07-31T19:47:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-06"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Engineering in Electrical Engineering and Computer Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/151536"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Vascular diseases such as atherosclerosis are a leading cause of mortality and morbidity worldwide. Intravascular Ultrasound (IVUS) is an imaging technology that has the distinctive ability to offer real-time endovascular information of the coronary vasculature. However, its low signal-to-noise ratio, low data availability, and numerous artifacts make it challenging to use both for humans and automated methods. This work explores the use of representation learning and de-noising techniques to address these challenges and aid in the diagnosis of vascular diseases. We test our methods on the task of stent malapposition detection, where naive approaches fail discouragingly. We improve the naive baseline accuracy by 16%. In addition, we develop a deep learning approach for real-time stabilization of the IVUS videos, which performs registration 20-fold faster than the classical ANTs approach. Our results demonstrate the importance of incorporating domain knowledge in performance improvement while still indicating the limitations of current systems for achieving clinically ready performance."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:title","label":"Title","values":["Unsupervised Representation Learning from Intravascular Ultrasound Videos"]}]}],"canonical_facts":{"dc:contributor.advisor":["Golland, Polina"],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science"],"dc:creator":["Jain, Lay"],"dc:date.accessioned":["2023-07-31T19:47:00Z"],"dc:date.available":["2023-07-31T19:47:00Z"],"dc:date.issued":["2023-06"],"dc:description.abstract":["Vascular diseases such as atherosclerosis are a leading cause of mortality and morbidity worldwide. Intravascular Ultrasound (IVUS) is an imaging technology that has the distinctive ability to offer real-time endovascular information of the coronary vasculature. However, its low signal-to-noise ratio, low data availability, and numerous artifacts make it challenging to use both for humans and automated methods. This work explores the use of representation learning and de-noising techniques to address these challenges and aid in the diagnosis of vascular diseases. We test our methods on the task of stent malapposition detection, where naive approaches fail discouragingly. We improve the naive baseline accuracy by 16%. In addition, we develop a deep learning approach for real-time stabilization of the IVUS videos, which performs registration 20-fold faster than the classical ANTs approach. Our results demonstrate the importance of incorporating domain knowledge in performance improvement while still indicating the limitations of current systems for achieving clinically ready performance."],"dc:description.degree":["M.Eng."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/151536"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Unsupervised Representation Learning from Intravascular Ultrasound Videos"],"dc:type":["Thesis"],"thesis:degree_name":["Master","Master of Engineering in Electrical Engineering and Computer Science"]},"updated_at":"2026-07-22T22:22:22Z"}