Back to results

Massachusetts Institute of Technology

A modular and stretchable electronic system for on-body health monitoring applications

Abstract

dc:description.abstract

Most of current wearable devices used for health monitoring (e.g. Fitbit) are composed of bulky rigid electronics that are not customizable and are too rigid for the skin. To overcome such limitations, a modular system based on thin and stretchable electronic modules was proposed. To link modules together, a novel four pin sliding connector was designed, fabricated, integrated into an stretchable electronic circuit and characterized. The first part of the thesis focused on investigating different stretchable conductive materials that could be integrated into soft rubber substrates. Two materials were tested. First, a commercial silver ink was deposited onto polyurethane rubber (PUR), showing high conductivity but minimum stretchability (below 3% strain). Second, serpentine shaped FPCs were designed and integrated into a silicone substrate, showing stretchability up to 160-170% strain with minimum changes in conductivity (below 30%). Additionally, a tensile cycling test showed stable electromechanical behavior up to 3,500 cycles at 30% maximum tensile strain. The second part of this work addressed the design, fabrication and testing of a novel system for modular stretchable electronics. A four pin sliding connector to enable I2C communication was fabricated by assembling 3D printed parts with brass components manufactured with an EDM cutter. The mechanism could be easily integrated within the previously made stretchable FPC serpentines and demonstrated excellent electromechanical performance. A sample module could be stretched until complete serpentine failure (120% strain) with resistance values across the four pins lower than 2[omega]. Furthermore, the device evaluation on a treadmill showed changes in resistance lower than 4.27[omega] during the 15 minute experiments.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Núñez López, Carlos, author.
Advisor dc:contributor.advisor
  • Joseph A. Paradiso.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/150466
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/150466

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Núñez López, Carlos, author.. A modular and stretchable electronic system for on-body health monitoring applications. Massachusetts Institute of Technology, 2019. https://hdl.handle.net/1721.1/150466