Back to results

Massachusetts Institute of Technology

Design of a low-cost high-performance flexural six degree-of-freedom positioning stage

Abstract

dc:description.abstract

This thesis introduces a new family of high-performance, low-cost, six-degree-of-freedom positioning systems for high-dynamic, high-accuracy applications. This machine is designed to achieve sub-micron (~~ 50nm) accuracy with meso-scale (~~ 1mm) motions with simple machine elements and commercially available components. The motion platform presented is a parallel kinematic machine supported by six flexural legs that each ride on a ball screw assembly. The required degrees of freedom and range of motion for the flexural and rolling elements are analyzed. The stiffness and stress analysis of each element is presented along with a model for system level stiffness, inertia, and natural frequency. A forward kinematic model describes how the motions of individual actuators can be directly related to the motions of the output stage, unlike a traditional hexapod which requires inverse kinematics. This thesis presents initial sizing rules of thumb, fundamental scaling laws, simulation and experimental results, and practical considerations for manufacturing. Prototypes were built and tested to confirm the models presented and inform the design of future machines. The operating theory of this machine can be extended beyond the exact elements described for applications which require larger range of motion, higher load capacity, or only need quasi-static operation.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Owen, Elliot Douglas, author.
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/150465
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/150465

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Owen, Elliot Douglas, author.. Design of a low-cost high-performance flexural six degree-of-freedom positioning stage. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/150465