Abstract

dc:description.abstract

Rheology is a key part of modern society, but the devices used to measure complex fluids are large and expensive, making them unobtainable for individuals or small organizations. This thesis presents the first and second prototypes of an effort to design an accurate but low-cost (<$200) rheometer using fused deposition modeling 3-dimensional printing (FDM 3D printing) and off-the-shelf components. Both designs utilized a cylinder rotating concentrically inside a cylindrical cup of sample fluid. The first prototype used an encoded direct current (DC) motor to rotate at a constant rate while measuring the motor current draw to estimate torque and was able to measure a fluid viscosity standard with η = 100 Pa.s within 17% of the known value. The second prototype used a microstepping stepper motor to rotate at a constant rate while using a loadcell to measure the reaction torque on the cup used to hold the sample and was able to measure a η = 0.1 Pa.s sample within 18% of the actual value. The second prototype was also able to measure viscosity vs shear rate curves for shear-thinning fluids over shear rates from 22.6 to 3.8 s-1 all at a cost less than 0.4% that of a laboratory rheometer (DHR-3; TA Instruments) which was used to obtain the comparison data. Finally, this thesis suggests changes to improve the accuracy and versatility of future designs.

Degree

thesis:*
Name thesis:degree_name
Bachelor
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Erni, Makita F.
Advisor dc:contributor.advisor
  • Trumper, David L.

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/144832
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/144832

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Erni, Makita F.. Electro-Mechanical Design and Testing of a Prototype Low-Cost Rheometer. Massachusetts Institute of Technology, 2022. https://hdl.handle.net/1721.1/144832