Back to results

Massachusetts Institute of Technology

Examining the feasibility of a novel ground-storage cooling system

Abstract

dc:description.abstract

The Boston climate is known for its long, cold winters but it also suffers from hot, humid summers. The dehumidification needed to maintain occupant comfort in summer is often provided by condensing the excess moisture onto surfaces cooled by cold water. The systems currently used to provide the cold water have limited efficiencies, so alternative systems must be sought in order to achieve reductions in building energy use and to reduce the rate of climate change. This research examines the feasibility of a ground-cooling storage system that stores the abundant Boston winter cold in an underground block of soil to provide dehumidification in summer. In winter, heat exchangers use the cold air to produce cold water, which flows through a set of pipes in the soil block, cooling the soil. In summer, the cooling stored in the soil block is used to provide cold water for the dehumidifier, thus meeting the latent cooling loads of the building. The physical scale of the system required was found to be reasonable, relative to typical building sizes. The soil block, which does not use any valuable program space, was sized as less than 10% of the overall building size and did not require deep excavation. Winter thermal modeling showed that the soil block could be fully charged in a typical winter season. The summer thermal modeling showed that the system can meet the majority of the building cooling loads and is capable of responding to cooling peaks. The system energy use is primarily driven by the use of the heat exchangers for winter charging. The system was estimated to have a coefficient of performance of 71, which is much higher than that of comparable systems used for dehumidification. In conclusion, this feasibility study found that the proposed system shows promising results as an alternative to conventional systems and is worth further investigation.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Architecture
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tang Liwen, Nicole.
Advisor dc:contributor.advisor
  • Leon R. Glicksman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/138580
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/138580

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Tang Liwen, Nicole.. Examining the feasibility of a novel ground-storage cooling system. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/138580