Back to results

Massachusetts Institute of Technology

Flow optimization of ventricular catheters for shear stress-induced death of astrocytes

Abstract

dc:description.abstract

The ventricular catheter for treatment of hydrocephalus has a low lifespan due to obstruction by brain tissue. Multiple catheter designs have been proposed, but breakthroughs have not been made yet particularly due to the lack of understanding of the obstruction mechanisms that appear to be coupled with the fluid dynamics of ventricular catheters and cerebrospinal fluid (CSF). Recent studies have shown that glial tissue, which is mainly comprised of astrocytes, is the major contributor to obstruction. Impeding glial tissue formation should then be the foremost goal of the next-generation catheter, which leaves a crucial question that has not been answered yet: How does the fluid dynamics of ventricular catheters affect glial tissue formation? Answering this question, this thesis suggests a new design objective based on in vitro microfluidic experiments on astrocytes and proposes a novel design scheme developed on a lumped-element model describing the fluid dynamics of ventricular catheters. The thesis conducted long-term in vitro microfluidic culture of astrocytes and showed that fluid shear stress inhibits astrocytes from increasing confluency and reduces their viability. In light of the result, using Computational Fluid Dynamics (CFD) simulations, we showed that the conventional geometry of ventricular catheters is vulnerable to astrocytes ingrowth. To find improved catheter geometries, we performed a numerical optimization based on a lumped-element model. We validated the lumped-element model against CFD simulations also in good agreement with the direct flow visualization we performed in the actual catheters. Apart from flow analysis, CSF was investigated, determining its range of surface tension and showing it to be shear thinning at low shear rates. Finally, we propose a new design paradigm for more robust catheters for hydrocephalus patients.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Sungkwon(Mechanical engineer)Massachusetts Institute of Technology.
Advisor dc:contributor.advisor
  • Lydia Bourouiba and Thomas Heldt.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/132739
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/132739

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lee, Sungkwon(Mechanical engineer)Massachusetts Institute of Technology.. Flow optimization of ventricular catheters for shear stress-induced death of astrocytes. Massachusetts Institute of Technology, 2019. https://hdl.handle.net/1721.1/132739