Back to results

Massachusetts Institute of Technology

Design and applications of cold-cathode X-ray imaging systems

Abstract

dc:description.abstract

X-ray computed tomography (CT) and planar x-ray imaging are mainstays of modern clinical care. The electron generation mechanism in standard x-ray tubes - specifically, a thermionic cathode - is reliable and capable of high current. However, thermionic cathodes are bulky, and cannot be pulsed quickly. Non-thermionic ('cold-cathode') electron generation can be exploited to make a smaller and rapidly pulsable x-ray source. Such an x-ray source could improve not just the portability of x-ray devices, but would allow for a CT system to operate by pulsing a distributed ring of x-ray sources instead of rotating a single large x-ray source. Furthermore, cold-cathode x-ray sources could allow for new signal acquisition and processing paradigms in the x-ray domain. This includes time-based image acquisition techniques, such as elastography and photon-counting measurements. In this dissertation, I discuss (1) the development of two novel types of cold-cathode x-ray sources: an ultraviolet photocathode-based source, and a silicon field emission chip; (2) novel methods for planar x-ray image acquisition, including a demonstration of dynamic x-ray elastography using a pulsed photocathode x-ray source; and (3) applications of modern signal processing techniques to the tomographic image reconstruction problem. In an epilogue, I discuss our research on N95 respirator sterilization and re-use for crisis situations.

Degree

thesis:*
Name thesis:degree_name
Doctoral
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cramer, Avilash(Avilash Kalpathy)
Advisor dc:contributor.advisor
  • Rajiv Gupta.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/130711
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/130711

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Cramer, Avilash(Avilash Kalpathy). Design and applications of cold-cathode X-ray imaging systems. Massachusetts Institute of Technology, 2021. https://hdl.handle.net/1721.1/130711