The process of unit dose continuous lyophilization consists of moving vials containing unit doses of pharmaceutical product though a series of process chambers with varying pressures and temperatures. In order to move the vials between process chambers with varying pressures without disturbing the conditions within each respective chamber, a load lock is required. Although load locks are commonly used in the semiconductor industry, existing designs are not directly applicable to the unit dose continuous lyophilization process due to the unique geometric constraints on the system. This thesis document details the design of a load-lock door for the unit dose continuous lyophilization process. To meet the load-lock door functional requirements, a four-bar linkage load-lock door and a load-lock door with ground pivots offset from the sealing surface were designed. Because the driving performance parameters cannot be reliably modeled, the seal performance, particle generation, and seal adhesion of each design will be experimentally tested. The highest performing design will be chosen and improved based on the experimental results.

Degree

thesis:*
Name thesis:degree_name
Bachelor
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Flores, Ryan Maximiliano.
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/127917
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/127917

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Flores, Ryan Maximiliano.. Design of load-lock door for unit dose continuous lyophilization process for complex biologics. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/127917