{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/127703"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/127703","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Shielding design for the time-resolving Magnetic Recoil Spectrometer (MRSt) on the National Ignition Facility (NIF)","abstract":"Abstract The National Ignition Facility (NIF) is one of the premier inertial confinement fusion (ICF) experiments active today, with the goal of acheiving ignition in a laboratory for the first time. Multiple diagnostics are needed to generate the scientific data necessary for guiding these experiments at the NIF toward this goal. The time-resolving Magnetic Recoil Spectrometer (MRSt) aims to provide time-resolved measurements of the neutron spectrum, to determine time evolution of ion temperature, areal density, and neutron yield, at a time resolution of 20ps and an energy resolution of 100 keV. This would be the first time-resolved measurement of these quantities, and is crucial to understanding the dynamics of the implosion and possible deviations from optimal performance. The MRSt's unique ability to diagnose the hot-spot formation, fuel assembly, and alpha heating will open a new door to ICF. This work establishes a conceptual shielding design for the MRSt that meets the signal-to-background requirements. The finalized design is composed of 65cm of 30% borated polyethylene shielding for the neutron background, and a 2.5cm layer of tungsten gamma shielding with a 5.5cm layer of shielding on the last 20cm of the pulse dilation drift tube (PDDT) detector. This design reduces the background about 300 times, from 0.12 for the unshielded design to 35 for the finalized shielding design, thus exceeding the requirement of S/B > 5 for the down-scattered-neutron measurement. Neutron background has been reduced nearly to zero, but further gamma reduction could be a future avenue of research, specifically surrounding the graded-Z shielding design.","abstract_html":"Abstract The National Ignition Facility (NIF) is one of the premier inertial confinement fusion (ICF) experiments active today, with the goal of acheiving ignition in a laboratory for the first time. Multiple diagnostics are needed to generate the scientific data necessary for guiding these experiments at the NIF toward this goal. The time-resolving Magnetic Recoil Spectrometer (MRSt) aims to provide time-resolved measurements of the neutron spectrum, to determine time evolution of ion temperature, areal density, and neutron yield, at a time resolution of 20ps and an energy resolution of 100 keV. This would be the first time-resolved measurement of these quantities, and is crucial to understanding the dynamics of the implosion and possible deviations from optimal performance. The MRSt&#x27;s unique ability to diagnose the hot-spot formation, fuel assembly, and alpha heating will open a new door to ICF. This work establishes a conceptual shielding design for the MRSt that meets the signal-to-background requirements. The finalized design is composed of 65cm of 30% borated polyethylene shielding for the neutron background, and a 2.5cm layer of tungsten gamma shielding with a 5.5cm layer of shielding on the last 20cm of the pulse dilation drift tube (PDDT) detector. This design reduces the background about 300 times, from 0.12 for the unshielded design to 35 for the finalized shielding design, thus exceeding the requirement of S/B &gt; 5 for the down-scattered-neutron measurement. Neutron background has been reduced nearly to zero, but further gamma reduction could be a future avenue of research, specifically surrounding the graded-Z shielding design.","abstract_has_math":false,"creators":["Sandberg, Alexander Jerome."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","school":null,"contributors":[],"advisors":["Johan Frenje and Zachary Hartwig."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-07-22T22:21:38Z","subjects":["Nuclear Science and Engineering."],"languages":["eng"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/127703","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Johan Frenje and Zachary Hartwig."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","NucEng"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Sandberg, Alexander Jerome."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-25T20:03:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-25T20:03:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/127703"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Thesis: S.M., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2019","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 49-50)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Abstract The National Ignition Facility (NIF) is one of the premier inertial confinement fusion (ICF) experiments active today, with the goal of acheiving ignition in a laboratory for the first time. Multiple diagnostics are needed to generate the scientific data necessary for guiding these experiments at the NIF toward this goal. The time-resolving Magnetic Recoil Spectrometer (MRSt) aims to provide time-resolved measurements of the neutron spectrum, to determine time evolution of ion temperature, areal density, and neutron yield, at a time resolution of 20ps and an energy resolution of 100 keV. This would be the first time-resolved measurement of these quantities, and is crucial to understanding the dynamics of the implosion and possible deviations from optimal performance. The MRSt's unique ability to diagnose the hot-spot formation, fuel assembly, and alpha heating will open a new door to ICF. This work establishes a conceptual shielding design for the MRSt that meets the signal-to-background requirements. The finalized design is composed of 65cm of 30% borated polyethylene shielding for the neutron background, and a 2.5cm layer of tungsten gamma shielding with a 5.5cm layer of shielding on the last 20cm of the pulse dilation drift tube (PDDT) detector. This design reduces the background about 300 times, from 0.12 for the unshielded design to 35 for the finalized shielding design, thus exceeding the requirement of S/B > 5 for the down-scattered-neutron measurement. Neutron background has been reduced nearly to zero, but further gamma reduction could be a future avenue of research, specifically surrounding the graded-Z shielding design."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Shielding design for the time-resolving Magnetic Recoil Spectrometer (MRSt) on the National Ignition Facility (NIF)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Johan Frenje and Zachary Hartwig."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","NucEng"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."],"dc:creator":["Sandberg, Alexander Jerome."],"dc:date.accessioned":["2020-09-25T20:03:14Z"],"dc:date.available":["2020-09-25T20:03:14Z"],"dc:date.issued":["2019"],"dc:description":["This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Thesis: S.M., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2019","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 49-50)."],"dc:description.abstract":["Abstract The National Ignition Facility (NIF) is one of the premier inertial confinement fusion (ICF) experiments active today, with the goal of acheiving ignition in a laboratory for the first time. Multiple diagnostics are needed to generate the scientific data necessary for guiding these experiments at the NIF toward this goal. The time-resolving Magnetic Recoil Spectrometer (MRSt) aims to provide time-resolved measurements of the neutron spectrum, to determine time evolution of ion temperature, areal density, and neutron yield, at a time resolution of 20ps and an energy resolution of 100 keV. This would be the first time-resolved measurement of these quantities, and is crucial to understanding the dynamics of the implosion and possible deviations from optimal performance. The MRSt's unique ability to diagnose the hot-spot formation, fuel assembly, and alpha heating will open a new door to ICF. This work establishes a conceptual shielding design for the MRSt that meets the signal-to-background requirements. The finalized design is composed of 65cm of 30% borated polyethylene shielding for the neutron background, and a 2.5cm layer of tungsten gamma shielding with a 5.5cm layer of shielding on the last 20cm of the pulse dilation drift tube (PDDT) detector. This design reduces the background about 300 times, from 0.12 for the unshielded design to 35 for the finalized shielding design, thus exceeding the requirement of S/B > 5 for the down-scattered-neutron measurement. Neutron background has been reduced nearly to zero, but further gamma reduction could be a future avenue of research, specifically surrounding the graded-Z shielding design."],"dc:description.degree":["S.M."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/127703"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Shielding design for the time-resolving Magnetic Recoil Spectrometer (MRSt) on the National Ignition Facility (NIF)"],"dc:type":["Thesis"],"thesis:degree_name":["Master"]},"updated_at":"2026-07-22T22:21:38Z"}