Back to results

Massachusetts Institute of Technology

Optimizing thermal spray quality verification in FAA repair station specializing in rotating components

Abstract

dc:description.abstract

Thermal spray is a manufacturing process where melted particles are sprayed onto a surface to build up thickness. It is used extensively in the aerospace industry to improve and repair part surfaces, extending the useful life of expensive components. Because thermal spray is a special process, current quality practices require destructive testing. Because testing using production parts is expensive, quality management is commonly done through the use of representative test coupons. However, the coupon process is both financially expensive and operationally inefficient. Connecticut Rotating Parts (CTRP) is an FAA Part 145 repair station specializing in rotating hardware. Thermal spray is used at multiple stages during the repair process so the continued operation of its spray booths are critical to meeting delivery dates. Currently, CTRP runs weekly coupons for every material and spray booth combination. Each test cycle is at least 24 hours during which no parts can be sprayed. The objective of this thesis is to use CTRP as a benchmark to investigate thermal spray quality related issues in order to evaluate best practice quality control methods. Specifically, this project evaluated a camera system that monitors the state of the particles prior to substrate contact as an indirect measure of buildup quality. An analysis of CTRP's historical coupon and production performance showed very few failures. The failures that did occur were most likely the result of isolated deviations rather than systemic faults. Testing of the camera system was unable to conclusively establish the parameters needed for regular plume and equipment monitoring. These findings suggest that existing process controls are very capable of producing high quality coatings even in high turnover shops like CTRP and that weekly testing may be overly conservative. However, non-destructive testing methods do not yet exist that can sufficiently replace the utility of representative coupons.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Sloan School of Management
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Lingmiao.
Advisor dc:contributor.advisor
  • R. John Hansman and Roy E. Welsch.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/126986
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/126986

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wang, Lingmiao.. Optimizing thermal spray quality verification in FAA repair station specializing in rotating components. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/126986