{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/121808"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/121808","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Spectral analysis of integrated F-center feedback dosimeter","abstract":"Proton therapy has yet to implement an in-vivo, real-time, fault-tolerant integral dosimeter. Proposed in this thesis is a conceptual dosimeter to meet such requirements, relying on the radiation-stimulated production of F-centers in alkali halide salts. F-centers are optically active vacancies in the cation-anion lattice filled with a lone electron. These vacancies cause dimming bands in broad-band illumination of the crystal, and the vacancies increase in number in a proportional fashion to the dose received. The experiment proposed here will serve both to measure the dimming quality of various alkali halide salts as well as their decay rate in the dark at room temperature. Once performed, this experiment will demonstrate the feasibility of correlating dose to a real-time color measurement of an implanted alkali halide crystal in a patient undergoing proton radiotherapy. Thus far no such experiments have been performed, however the experimental assembly outlined herein is nearly fully constructed and nearly ready for experimentation upon time of completing this thesis.","abstract_html":"Proton therapy has yet to implement an in-vivo, real-time, fault-tolerant integral dosimeter. Proposed in this thesis is a conceptual dosimeter to meet such requirements, relying on the radiation-stimulated production of F-centers in alkali halide salts. F-centers are optically active vacancies in the cation-anion lattice filled with a lone electron. These vacancies cause dimming bands in broad-band illumination of the crystal, and the vacancies increase in number in a proportional fashion to the dose received. The experiment proposed here will serve both to measure the dimming quality of various alkali halide salts as well as their decay rate in the dark at room temperature. Once performed, this experiment will demonstrate the feasibility of correlating dose to a real-time color measurement of an implanted alkali halide crystal in a patient undergoing proton radiotherapy. Thus far no such experiments have been performed, however the experimental assembly outlined herein is nearly fully constructed and nearly ready for experimentation upon time of completing this thesis.","abstract_has_math":false,"creators":["Schumaker, Daniel(Daniel C.)"],"institution":"Massachusetts Institute of Technology","degree_name":"Bachelor","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","school":null,"contributors":[],"advisors":["Michael P. Short."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-07-22T22:21:04Z","subjects":["Nuclear Science and Engineering."],"languages":["eng"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/121808","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Michael P. Short."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","NucEng"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Schumaker, Daniel(Daniel C.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-07-18T20:31:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-07-18T20:31:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Bachelor"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/121808"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2018","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 48-53)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Proton therapy has yet to implement an in-vivo, real-time, fault-tolerant integral dosimeter. Proposed in this thesis is a conceptual dosimeter to meet such requirements, relying on the radiation-stimulated production of F-centers in alkali halide salts. F-centers are optically active vacancies in the cation-anion lattice filled with a lone electron. These vacancies cause dimming bands in broad-band illumination of the crystal, and the vacancies increase in number in a proportional fashion to the dose received. The experiment proposed here will serve both to measure the dimming quality of various alkali halide salts as well as their decay rate in the dark at room temperature. Once performed, this experiment will demonstrate the feasibility of correlating dose to a real-time color measurement of an implanted alkali halide crystal in a patient undergoing proton radiotherapy. Thus far no such experiments have been performed, however the experimental assembly outlined herein is nearly fully constructed and nearly ready for experimentation upon time of completing this thesis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Spectral analysis of integrated F-center feedback dosimeter"]}]}],"canonical_facts":{"dc:contributor.advisor":["Michael P. Short."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering","NucEng"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."],"dc:creator":["Schumaker, Daniel(Daniel C.)"],"dc:date.accessioned":["2019-07-18T20:31:21Z"],"dc:date.available":["2019-07-18T20:31:21Z"],"dc:date.issued":["2018"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2018","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 48-53)."],"dc:description.abstract":["Proton therapy has yet to implement an in-vivo, real-time, fault-tolerant integral dosimeter. Proposed in this thesis is a conceptual dosimeter to meet such requirements, relying on the radiation-stimulated production of F-centers in alkali halide salts. F-centers are optically active vacancies in the cation-anion lattice filled with a lone electron. These vacancies cause dimming bands in broad-band illumination of the crystal, and the vacancies increase in number in a proportional fashion to the dose received. The experiment proposed here will serve both to measure the dimming quality of various alkali halide salts as well as their decay rate in the dark at room temperature. Once performed, this experiment will demonstrate the feasibility of correlating dose to a real-time color measurement of an implanted alkali halide crystal in a patient undergoing proton radiotherapy. Thus far no such experiments have been performed, however the experimental assembly outlined herein is nearly fully constructed and nearly ready for experimentation upon time of completing this thesis."],"dc:description.degree":["S.B."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/121808"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Spectral analysis of integrated F-center feedback dosimeter"],"dc:type":["Thesis"],"thesis:degree_name":["Bachelor"]},"updated_at":"2026-07-22T22:21:04Z"}