Back to results

Massachusetts Institute of Technology

Genetically encodable calcium sensors for Magnetic Resonance Imaging

Abstract

dc:description.abstract

A key requirement for understanding the workings of the brain is to fill in the explanatory gap between molecular phenomena and identifiable behavior at the organismal level. Magnetic resonance imaging (MRI) provides a unique tool for bridging this gap, as it allows for imaging tissue throughout whole organisms. Although functional MRI (fMRI) is already a workhorse technique in human neuroscience research, current fMRI methods give us limited information about brain mechanisms because they rely on blood flow changes that are only indirectly coupled to cellular and molecular events. To associate cellular or molecular specificity to MRI, there is a need for genetically targeted, analyte-specific sensors. Calcium is a molecule of great interest to biology since its fluctuations are highly correlated with neural activity. While much progress has been made in pursuit of genetically encoded calcium sensors none allow for deep tissue imaging of whole rodent brains. In this thesis we demonstrate that genetically encodable calcium sensors based on known MRI gene reporter ferritin show modest sensitivity. To achieve higher amplification we leverage the hemodynamic response, which is coupled to neuronal activity through a calcium-activated enzyme, neuronal nitric oxide synthase (nNOS). We show that chemical stimulation of ectopically expressed neuronal nitric oxide synthase (nNOS) elicits an artificial hemodynamic response detectable by MRI. To distinguish signaling from endogenous nNOS we use a two-prong strategy to engineer a suite of enzymes with altered inhibition constants compared to nNOS. We demonstrate that these engineered enzymes (NOSTICs) exhibit calcium-dependent catalytic activity. One such NOSTIC was then virally delivered to rodent brains and shown to express in certain cell populations. Hemodynamic responses from these cell populations were recorded following electrical stimulation using MRI. The imaging strategy demonstrated here thus offers a novel and potentially powerful approach for cell-targeted functional imaging of the brain.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Biological Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ghosh, Souparno, Ph. D. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Alan Jasanoff.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/120443
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/120443

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ghosh, Souparno, Ph. D. Massachusetts Institute of Technology. Genetically encodable calcium sensors for Magnetic Resonance Imaging. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/120443