Back to results

Massachusetts Institute of Technology

Non-invasive system identification of a tactical generator

Abstract

dc:description.abstract

Microgrids, small power distribution networks, are gaining traction as an approach to increasing the fuel efficiency of tactical operations. In order to design controllers for microgrids, accurate models of the generators providing power are needed. In this thesis, non-invasive experimental methods for determining synchronous machine system parameters for a Tactical Quiet Generator (TQG), a generator commonly used by the US military, are explored. While the generator's rotor is at standstill, direct voltage excitation over a large range of excitation frequencies of a synchronous machine's stator is employed to determine electrical parameters for the synchronous machine. With the generator in running, the response of the frequency of generated AC power to a step in load is employed to determine the inertia of the generator's rotor. The stator excitation test is performed with the rotor positioned at a series of angles relative to the stator, so as to determine the location of the principal axes (d and q axes) of the rotor and impedances of the synchronous machine as seen in the d-q reference frame. Least-squares curve fitting is applied to the Bode plots of these impedances to fit the predictions of equivalent circuit models to the data, thus determining the model parameters represented by each equivalent circuit element. For the load step response test, the swing equation is used to calculate the system inertia from measured changes in frequency due to known steps in power. From execution of these techniques, it was determined that they are viable methods for estimating system parameters, though greater precision needs to be exercised in the stator excitation test in order to accurately estimate parameters.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bell, John Harry, IV
Advisor dc:contributor.advisor
  • Marija D. Ilic.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/120255
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/120255

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Bell, John Harry, IV. Non-invasive system identification of a tactical generator. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/120255