Back to results

Massachusetts Institute of Technology

Design and development of a smart, self-contained, portable negative pressure wound therapy device

Abstract

dc:description.abstract

Negative pressure wound therapy (NPWT) is a commonly used treatment in which the application of a low vacuum (-20kPa) is used to accelerate the recovery of chronic, hard-to-heal wounds. Costs of chronic wounds such as diabetic foot ulcers are estimated to be $25 billion, with 6.5 million patients being affected. Improving the portability and efficacy of NPWT devices will allow a larger migration of patients from hospital stays to at-home care. Current portable NPWT devices have severe limitations due to their size, inability to dynamically modulate pressure or handle large volumes of wound exudate. The work in this thesis was to develop a more portable NPWT device in which all functional components are self-contained within the bandage itself. To accomplish this goal, a soft-material, fuel-cell based actuator was designed and incorporated into a self contained, compact pumping mechanism. Additionally graphene-oxide barriers were designed to allow for fluid management at the wound site. The designed bandage was able to maintain negative pressure even at worst-case scenario leak rates (6.7 x 102 mL/s) and an exudate rate of 5.6 x 10-5 mL/s. The contributions from this thesis are a novel, soft-materials based actuator for use in biomedical applications and the further characterization of graphene-oxide barriers.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Modak, Ashin (Ashin Pramod)
Advisor dc:contributor.advisor
  • Ian W. Hunter.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/119769
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/119769

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Modak, Ashin (Ashin Pramod). Design and development of a smart, self-contained, portable negative pressure wound therapy device. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/119769