Back to results

Massachusetts Institute of Technology

Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway

Abstract

dc:description.abstract

Polyethylene (PE) passive samplers are capable of measuring in-situ, freely dissolved, time-averaged concentration distributions of contaminants in air, surface water, and sediment bed porewater. This sampling technique can be coupled with a three dimensional (3D) hydrodynamic model of a given surface water body to identify where sources contributing to the measured concentration distribution are most likely located and what mass flux is required to produce the measured concentrations. This evaluation was completed for the Lower Duwamish Waterway (LDW), a salt wedge estuary located in Seattle, Washington. The LDW was selected for its idealized conditions (straight channel with relatively uniform cross-section), established 3D hydrodynamic model (Environmental Fluid Dynamics Code [EFDC]), and availability of measured data. Density-driven circulation in the LDW drives saltwater upstream and freshwater downstream, influencing residence times, mixing times, and the resulting concentration distributions of potential sources. The dependence of simulated, unit strength concentration distributions on source location was evaluated by spatially comparing EFDC-simulated sources introduced at various points in the LDW. This determined how far apart potential sources need to be, referred to as a distinguishable distance, to be "resolved" by measured or modeled concentrations at the LDW centerline. East and west bank sources were generally distinguishable within 0.8 miles of introduction; water surface and sediment bed sources were generally distinguishable throughout the LDW; longitudinally distributed sources were distinguishable for 0.4 to 1.1 miles from the source location. PE passive samplers placed at the centerline of the LDW with spacing at or near the distinguishable distance will likely be able to differentiate between various source locations. Inverse model techniques were applied to measured concentration distributions in the water column using numerous cases of potential source locations with distinguishable, unit strength concentration distributions. The resulting mass fluxes ranged from 0.034 mg/s to 0.072 mg/s (average 0.043 mg/s), an order of magnitude higher than known source fluxes (i.e., sediment diffusive flux and air-water exchange flux). Therefore, one or more "missing sources" were determined to exist; based on this evaluation, it is possible the sources originate from the midstream sediment bed, upstream sediment bed, and upstream water surface.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sobchuk, Catherine Elizabeth
Advisor dc:contributor.advisor
  • E. Eric Adams.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/119323
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/119323

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Sobchuk, Catherine Elizabeth. Evaluating the combined use of three-dimensional hydrodynamic modeling and polyethylene passive sampling in the Lower Duwamish Waterway. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/119323