Fault-tolerant passively integrating in-vivo dosimeters for feedback-enabled proton therapy (IF²D, or integrating feedback F-center dosimeter)

Abstract

dc:description.abstract

Current dosimeters used in radiotherapy for cancer treatment fail to distinguish between radiation received by the targeted tumor and the surrounding healthy tissue. The Integrating Feedback F-center Dosimeter is designed to be fault-tolerant, with the capability to distinguish the radiation dose received between a targeted tumor and surrounding tissue. To provide a proof of concept of the IF²D, five alkali halide salts will be irradiated by a tandem electrostatic proton accelerator. These salts, (NaCl, NaI, NaBr, NaF, CsF), were chosen for their f-center properties which enable a direct conversion between the wavelength of the irradiated salt i.e. color change, and the expected radiation dose. We expect that analytical calculations between wavelength and expected radiation dose will correlate with experimental data. A direct conversion will enable the doctor to determine how much radiation the salt has received and therefore how much radiation dose the tumor itself has received. As a result, the patient will require less exposure time, and less radiation treatments, thus reducing the probability of obtaining secondary cancers. The following paper outlines the initial procedures taken to irradiate the selected salts and theoretical calculations that we expect to parallel future experimental data.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Iturbide, Rossana
Advisor dc:contributor.advisor
  • Michael P. Short.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/119043
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/119043

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Iturbide, Rossana. Fault-tolerant passively integrating in-vivo dosimeters for feedback-enabled proton therapy (IF²D, or integrating feedback F-center dosimeter). Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/119043