Back to results

Massachusetts Institute of Technology

Advanced functional and intraoperative ophthalmic optical coherence tomography imaging

Abstract

dc:description.abstract

Optical coherence tomography (OCT) is a non-contact, non-invasive imaging technique that uses optical interferometry to generate high-resolution, depth-resolved images of tissue in vivo. Ophthalmologists now use commercial OCT systems as a standard diagnostic instrument for imaging the retina to detect or monitor pathologies. However, prototype OCT research instruments exceed commercial systems in terms of faster imaging speeds and higher resolutions. Finding applications for these improvements will improve clinical utility for future OCT systems. This thesis describes the design and use of an ultrahigh resolution spectral domain OCT system for detecting the photoreceptor changes during flash stimulus and an ultrahigh resolution swept source OCT system for use in eye surgery. The ultrahigh axial resolution of our system enabled visualization of thickness changes in the outer retinal layers after flash stimulus and subsequent dark adaptation. This finding could be used as a marker for photoreceptor health in retinal diseases that influence dark adaptation such as age-related macular degeneration. In the operating room, the ultrahigh speed system attaches to the operating microscope to share the surgeon's view and provide depth-resolved information that is not possible with the standard surgeon's stereoscopic view. This allows for imaging during surgical procedures and the ultrahigh speed enables acquisition of dense, widefield data sets as well as rapid volume acquisition to generate 3D visualizations in time. These data sets will enable 3D planning of procedures, assessment of outcomes before leaving the operating room, and feedback for surgical procedures.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lu, Chen David
Advisor dc:contributor.advisor
  • James G. Fujimoto.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/115764
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/115764

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lu, Chen David. Advanced functional and intraoperative ophthalmic optical coherence tomography imaging. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/115764