Back to results

Massachusetts Institute of Technology

Design and testing of wearable and long-term subdermal implantable electroencephalograms

Abstract

dc:description.abstract

Electroencephalography (EEG) has long been used by neurologists to aid in diagnosing and treating neurological disorders ranging from sleep apnea to epilepsy. However, inherent difficulties still exist in capturing EEG data for extended periods of time on the order of days to weeks in humans. Such difficulties brought on by implementation challenges and usability ultimately lead to patient non-compliance. These challenges also curtail EEG use in sleep studies due to complexity of setup. This work aims to address these issues by extending the functionality and performance of a previously designed EEG ASIC. A design for a subdermal, implantable EEG recording system for long term EEG monitoring as well as a simplified wearable and wireless EEG sensor is realized. The implantable design is an 8-channel, 250Hz bandwidth EEG system in a 14.0mm x 15.5mm package that is wirelessly powered by an external device through inductively coupled coils with backscattering. The device is placed subdermally above the skull for continuous patient EEG monitoring for up to a month to aid neurologists with epilepsy diagnosis. This device is especially important given the severity of antiepileptic drugs' side-effects. The performance of this device is verified through animal studies in pigs. This work is also extended to the design of a wearable, wireless EEG patch for sleep studies. The device is a 20mm x 24mm, 4-channel, 250Hz bandwidth, Bluetooth Low-Energy (BTLE) electronics package with adhesive electrodes that can be quickly applied. This device is aimed to assist neurologists and clinicians perform sleep studies. Results are verified using sleep data collected on the author.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Jason, M. Eng. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Charles G. Sodini.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/113456
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/113456

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation