{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/113108"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/113108","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A 64 channel 3T array coil for highly accelerated fetal imaging at 22 weeks of pregnancy","abstract":"MRI is an attractive tool for fetal imaging due to its unique ability to provide detailed anatomical and physiological data in an inherently safe manner. In practice, the problem of unpredictable and nonrigid fetal motion limits fetal MRI to fast single shot T2 weighted sequences such as HASTE, which have poor tissue contrast, low SNR, and cannot provide detailed physiological information. In this work, we designed, built, and tested a semi-adjustable anatomically shaped 64 channel array coil for fetal imaging at 22 weeks of pregnancy. The coil's performance was compared to that of the vendor's standard configuration consisting of an 18 channel flexible body array and 16 channels from a 32 channel spine array. The fetal coil provides roughly 5% better SNR in the fetal brain region of an anthropomorphic phantom and allows increasing SENSE acceleration factor from R = 4 to R = 5 in the right-left direction and R = 3 to R = 4 in the head-foot direction.","abstract_html":"MRI is an attractive tool for fetal imaging due to its unique ability to provide detailed anatomical and physiological data in an inherently safe manner. In practice, the problem of unpredictable and nonrigid fetal motion limits fetal MRI to fast single shot T2 weighted sequences such as HASTE, which have poor tissue contrast, low SNR, and cannot provide detailed physiological information. In this work, we designed, built, and tested a semi-adjustable anatomically shaped 64 channel array coil for fetal imaging at 22 weeks of pregnancy. The coil&#x27;s performance was compared to that of the vendor&#x27;s standard configuration consisting of an 18 channel flexible body array and 16 channels from a 32 channel spine array. The fetal coil provides roughly 5% better SNR in the fetal brain region of an anthropomorphic phantom and allows increasing SENSE acceleration factor from R = 4 to R = 5 in the right-left direction and R = 3 to R = 4 in the head-foot direction.","abstract_has_math":false,"creators":["Spatz, Mark H"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Lawrence L. Wald."],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-07-22T22:21:19Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/113108","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lawrence L. Wald."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Spatz, Mark H"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-12T20:56:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-12T20:56:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/113108"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2017.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (page 65)."]},{"key":"dc:description.abstract","label":"Abstract","values":["MRI is an attractive tool for fetal imaging due to its unique ability to provide detailed anatomical and physiological data in an inherently safe manner. In practice, the problem of unpredictable and nonrigid fetal motion limits fetal MRI to fast single shot T2 weighted sequences such as HASTE, which have poor tissue contrast, low SNR, and cannot provide detailed physiological information. In this work, we designed, built, and tested a semi-adjustable anatomically shaped 64 channel array coil for fetal imaging at 22 weeks of pregnancy. The coil's performance was compared to that of the vendor's standard configuration consisting of an 18 channel flexible body array and 16 channels from a 32 channel spine array. The fetal coil provides roughly 5% better SNR in the fetal brain region of an anthropomorphic phantom and allows increasing SENSE acceleration factor from R = 4 to R = 5 in the right-left direction and R = 3 to R = 4 in the head-foot direction."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M. Eng."]},{"key":"dc:title","label":"Title","values":["A 64 channel 3T array coil for highly accelerated fetal imaging at 22 weeks of pregnancy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lawrence L. Wald."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Spatz, Mark H"],"dc:date.accessioned":["2018-01-12T20:56:22Z"],"dc:date.available":["2018-01-12T20:56:22Z"],"dc:date.issued":["2017"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2017.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (page 65)."],"dc:description.abstract":["MRI is an attractive tool for fetal imaging due to its unique ability to provide detailed anatomical and physiological data in an inherently safe manner. In practice, the problem of unpredictable and nonrigid fetal motion limits fetal MRI to fast single shot T2 weighted sequences such as HASTE, which have poor tissue contrast, low SNR, and cannot provide detailed physiological information. In this work, we designed, built, and tested a semi-adjustable anatomically shaped 64 channel array coil for fetal imaging at 22 weeks of pregnancy. The coil's performance was compared to that of the vendor's standard configuration consisting of an 18 channel flexible body array and 16 channels from a 32 channel spine array. The fetal coil provides roughly 5% better SNR in the fetal brain region of an anthropomorphic phantom and allows increasing SENSE acceleration factor from R = 4 to R = 5 in the right-left direction and R = 3 to R = 4 in the head-foot direction."],"dc:description.degree":["M. Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/113108"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["A 64 channel 3T array coil for highly accelerated fetal imaging at 22 weeks of pregnancy"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:19Z"}