Causes and analysis of failures in in-situ microscopy observation for the characterization of scaling in membrane distillation membranes

Abstract

dc:description.abstract

In membrane technology at large, fouling limits membrane performance and membrane lifespan. In the case of reverse osmosis membrane distillation (MD) involving fluid mixtures of inorganic elements, inorganic foulants build up on membrane surfaces, and reduce the flux of fluids across a membrane. Inorganic fouling can degrade the quality of water produced by membrane distillation. In order to counteract the effects of membrane fouling, potentially costly procedures like intense chemical cleaning or membrane replacement are necessary. Some theory suggests that, instead of reacting and adhering to membrane surfaces, salts tend to bulk nucleate in solution, and then deposit on high energy surfaces, like metal heat exchangers and hydrophilic reverse osmosis membranes. This is in contrast to the theory that crystals first deposit on the membrane surface to cause fouling. A solution of Na2SO4. and CaCl, was pumped across a membrane at 70°C at 2.6 GPM (9.8 LPM) to observe membrane fouling. Using an in-situ camera, fouling on a membrane distillation surface was captured to characterize the nature of MD fouling. Due to failures in heat distribution across the solution and system leaking, no fouling on the membrane surface was observed.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Polanco, Pedro (Pedro D.)
Advisor dc:contributor.advisor
  • John H. Lienhard, V.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/112549
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/112549

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Polanco, Pedro (Pedro D.). Causes and analysis of failures in in-situ microscopy observation for the characterization of scaling in membrane distillation membranes. Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/112549