{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/112372"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/112372","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Designing an experiment to study absorption vs. dose for feedback enabled radiation therapy","abstract":"In the field of radiation oncology, while there are simulations and devices that allow users to be relatively confident that radiation to the tumor and sparing of healthy tissue is being maximized, the inability to reliably measure and control the dose during radiation treatment is a major source of uncertainty. This uncertainty is due to issues such as organ movement, a lack of precise and constant knowledge of beam current at the target site, and the inability to correctly register dose during hardware or software failures; all of which result in radiation treatments being measured after the procedure or in a fault susceptible manner during the procedure. The integrating feedback f-center dosimeter (IF2D) is a dosimeter that would address these challenges and enable feedback during radiotherapy procedures, which would give doctors and patients confidence that the correct dose was delivered to the target sites without exceeding allowable doses to healthy tissue. An in-situ irradiator will be designed and later used to quantify the relationship between dose and f-center absorption. This design will help guide the future experiment and further the development of the IF2D.","abstract_html":"In the field of radiation oncology, while there are simulations and devices that allow users to be relatively confident that radiation to the tumor and sparing of healthy tissue is being maximized, the inability to reliably measure and control the dose during radiation treatment is a major source of uncertainty. This uncertainty is due to issues such as organ movement, a lack of precise and constant knowledge of beam current at the target site, and the inability to correctly register dose during hardware or software failures; all of which result in radiation treatments being measured after the procedure or in a fault susceptible manner during the procedure. The integrating feedback f-center dosimeter (IF2D) is a dosimeter that would address these challenges and enable feedback during radiotherapy procedures, which would give doctors and patients confidence that the correct dose was delivered to the target sites without exceeding allowable doses to healthy tissue. An in-situ irradiator will be designed and later used to quantify the relationship between dose and f-center absorption. This design will help guide the future experiment and further the development of the IF2D.","abstract_has_math":false,"creators":["Green, Hadrick Alexis"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.","school":null,"contributors":[],"advisors":["Michael Short."],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-07-22T22:21:41Z","subjects":["Nuclear Science and Engineering."],"languages":["eng"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/112372","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Michael Short."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Green, Hadrick Alexis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-12-05T16:25:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-12-05T16:25:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/112372"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2017.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 43-44)."]},{"key":"dc:description.abstract","label":"Abstract","values":["In the field of radiation oncology, while there are simulations and devices that allow users to be relatively confident that radiation to the tumor and sparing of healthy tissue is being maximized, the inability to reliably measure and control the dose during radiation treatment is a major source of uncertainty. This uncertainty is due to issues such as organ movement, a lack of precise and constant knowledge of beam current at the target site, and the inability to correctly register dose during hardware or software failures; all of which result in radiation treatments being measured after the procedure or in a fault susceptible manner during the procedure. The integrating feedback f-center dosimeter (IF2D) is a dosimeter that would address these challenges and enable feedback during radiotherapy procedures, which would give doctors and patients confidence that the correct dose was delivered to the target sites without exceeding allowable doses to healthy tissue. An in-situ irradiator will be designed and later used to quantify the relationship between dose and f-center absorption. This design will help guide the future experiment and further the development of the IF2D."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Designing an experiment to study absorption vs. dose for feedback enabled radiation therapy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Michael Short."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."],"dc:creator":["Green, Hadrick Alexis"],"dc:date.accessioned":["2017-12-05T16:25:01Z"],"dc:date.available":["2017-12-05T16:25:01Z"],"dc:date.issued":["2017"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2017.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 43-44)."],"dc:description.abstract":["In the field of radiation oncology, while there are simulations and devices that allow users to be relatively confident that radiation to the tumor and sparing of healthy tissue is being maximized, the inability to reliably measure and control the dose during radiation treatment is a major source of uncertainty. This uncertainty is due to issues such as organ movement, a lack of precise and constant knowledge of beam current at the target site, and the inability to correctly register dose during hardware or software failures; all of which result in radiation treatments being measured after the procedure or in a fault susceptible manner during the procedure. The integrating feedback f-center dosimeter (IF2D) is a dosimeter that would address these challenges and enable feedback during radiotherapy procedures, which would give doctors and patients confidence that the correct dose was delivered to the target sites without exceeding allowable doses to healthy tissue. An in-situ irradiator will be designed and later used to quantify the relationship between dose and f-center absorption. This design will help guide the future experiment and further the development of the IF2D."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/112372"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Designing an experiment to study absorption vs. dose for feedback enabled radiation therapy"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:41Z"}