Massachusetts Institute of Technology
A multimodal breast cancer imaging system using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis
Abstract
dc:description.abstractDiffuse optical tomography (DOT) is an emerging noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional information overlay onto the mammographic images, increasing sensitivity and specificity to cancer pathology. We describe a dynamic DOT apparatus designed for tight integration with commercial DBT scanners and providing a fast (1 Hz+) image acquisition rate to enable tracking of hemodynamic changes induced by the mammographic breast compression. The most significant advance enabling fast acquisition was the design and construction of a direct analog-to-digital conversion frequency-domain near-infrared spectroscopy (FD-NIRS) component. It achieves simultaneous dual wavelength operation at 685 nm and 830 nm by concurrent 67.5 MHz and 75 MHz frequency modulation of each laser source, respectively, followed by digitization using a high-speed analog to digital converter and real-time hybrid FPGA-assisted demodulation by discrete Fourier transform (DFT). The overall DOT system integrates 96 CW-NIRS and 24 FD-NIRS source locations, as well as 32 CW-NIRS and 20 FD-NIRS detection locations into low-profile plates that mate to the DBT compression paddle and x-ray detector cover, respectively. The plates and the embedded optical fibers are made of plastic to minimize x-ray absorption and thus allow true simultaneous acquisition of the DBT image. We first characterize each major system component individually, and then demonstrate overall performance using static and dynamic tissue-like phantoms, as well as in vivo images acquired from the pool of patients recalled for breast biopsies at the Massachusetts General Hospital Breast Imaging Division.
Degree
thesis:*- Department dc:contributor.department
- Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 2017
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zimmermann, Bernhard B
- Advisor dc:contributor.advisor
-
- David A. Boas and Elfar Adalsteinsson.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1721.1/112045
- OAI identifier oai:identifier
- oai:dspace.mit.edu:1721.1/112045