Two-stage reverse osmosis : optimal element configuration and flux distribution, energy savings

Abstract

dc:description.abstract

In a two-stage reverse osmosis (RO) system of finite size, there are two degrees of freedom not present in a single-stage RO system: distribution of RO elements between the two stages (system design), and feed pressures (system operation). In this study, we investigate the optimal system design and operation of a two-stage RO system with a mass-balance model and establish a lower bound for the energy savings achieved by the optimized two-stage system compared to a single-stage system. A two-stage RO system may consume more or less energy than a single-stage RO system of the same size and freshwater productivity, depending on the first-stage feed pressure and second-stage feed pressure. To minimize energy consumption, feed pressures should be chosen to minimize spatial variance in flux. The optimal element configuration places at least half the elements in the first stage; the exact configuration depends on feed salinity, recovery ratio, and membrane permeability. The greatest energy savings are achieved with a two-stage RO system that has both optimal element configuration and feed pressures. More energy can be saved by adding a stage when the thermodynamic least work of separation is larger. For a given feed salinity, energy savings from adding a second stage grow as recovery ratio increases. Brackish water feeds must be taken to high recovery ratios to achieve substantial energy savings; comparable savings can be achieved at lower recovery ratios for higher salinity feeds. We find that significant energy can be saved with the simplest two-stage RO design, at a system flux similar to today's RO plants and accounting for the effects of concentration polarization.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wei, Quantum Jichi
Advisor dc:contributor.advisor
  • John H. Lienhard, V.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/111900
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/111900

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wei, Quantum Jichi. Two-stage reverse osmosis : optimal element configuration and flux distribution, energy savings. Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/111900