Back to results

Massachusetts Institute of Technology

Body coupled communication : the channel and implementation

Abstract

dc:description.abstract

To achieve comfortable form factors for wearable wireless medical devices, battery size, and thus power consumption, must be curtailed. Often the largest power consumption for wireless medical devices is storing or transmitting acquired data. Body area networks (BAN) can alleviate power budgets by using low power transmitters to send data locally around the body to receivers that are on areas of the body that allow for larger form factors, like the wrist or the waist. Body coupled communication (BCC) has been shown to have great potential in forming a BAN. This work expands the potential of BCC BANs by showing that BCC can include implanted nodes. Implants being able to implement BCC is an impactful discovery as previous BCC channel models have implicitly stated that BCC cannot work with implants. This discovery will allow BANs that include implants, such as pacemakers, to utilize the power efficiency of BCC. This thesis will give an introduction to BANs and BCC. It will further detail three contributions to BCC and its implementation. The three contributions are: 1) an excellent understanding of the BCC channel, that is verified by careful measurements, 2) a new amplifier circuit that improves the signal to interferer ratio, and 3) an asynchronous digital communication scheme that offers a high data rate and low power implementation. An integrated transmitter and receiver were fabricated in a 0.18 pm CMOS process. The results of the three contributions as implemented in the integrated chips are also presented and discussed. The integrated receiver was able to receive information at 16 Mbps, while consuming 5.9 mW, yielding an energy use of 367 pJ/bit. The integrated transmitter was able to transmit information at 30 Mbps, while consuming 4.32 mW, yielding an energy use of 114 pJ/bit.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Anderson, Grant Seaman
Advisor dc:contributor.advisor
  • Charles G. Sodini.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/111874
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/111874

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Anderson, Grant Seaman. Body coupled communication : the channel and implementation. Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/111874