Back to results

Massachusetts Institute of Technology

Can the phased array stimulation strategy be implemented using the advanced bionics cochlear implant?

Abstract

dc:description.abstract

Cochlear implants are devices that aim to restore a measure of hearing to the deaf by converting acoustic signals to electric stimuli delivered to electrodes implanted in the inner ear. Theoretically, the phased array stimulation strategy described by van den Honert and Kelsall (2007) provides much better control over the neural excitation patters elicited by electric stimulation by taking advantage of potential field superposition in the implanted cochlea, to construct stimuli for optimally selective excitation of auditory nerve fibers. If the phased array strategy can be implemented using a commonly-implanted commercial cochlear implant system, the strategy could be effectively evaluated in a relatively large sample of patients to determine whether it provides better speech reception than currently available systems. This thesis investigates whether the phased array strategy can be implemented using the Advanced Bionics Clarion CH or HiRes90k cochlear implant. It is shown that for realistic cochlear implant electrode impedance magnitudes, the Advanced Bionics cochlear implant current sources will deliver monopolar current suitable for the necessary measurement of transimpedance with less than 7% error. Transimpedance matrix estimates were obtained in 11 ears in 10 cochlear implant subjects. Measurements reveal that in some test subjects, low impedance current paths exist between implanted electrodes that may cause current leakage through unintended electrodes. Researchers and clinicians should consider using this transimpedance matrix estimation technique to screen for patients or research subjects who could benefit from compensatory changes to their speech processors. The results of this thesis suggest that the phased array strategy can be implemented successfully when the limitations of the internal power supply documented in this document are taken into account. It is recommended that the transimpedance matrix in a given test subject be measured on the day of any psychophysical testing because of the potential impact of variability in transimpedance over time.

Degree

thesis:*
Department dc:contributor.department
Harvard--MIT Program in Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Crema, Matthew V
Advisor dc:contributor.advisor
  • Donald K. Eddington.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/107333
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/107333

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Crema, Matthew V. Can the phased array stimulation strategy be implemented using the advanced bionics cochlear implant?. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/107333