Impact of x-ray dose on the response of CR-39 nuclear track detector to 1-5.5 MeV alphas and 0.5-9.1 MeV protons for spectroscopy at the OMEGA Laser Facility and the National Ignition Facility

Abstract

dc:description.abstract

The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to protons and alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 30 and 8keV Cu-K[alpha] and K[beta] x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas or 0.5- 9.1 MeV protons. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0±0.1 Gy causes a decrease of (19±2)% in the track diameter of a 5.5 MeV alpha, while a dose of 6.0±0.1 Gy results in a decrease of (29±1)% in the track diameter of a 3.0 MeV proton. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect, due to changes in track etch rate and dependent on incident particle energy, was characterized by an empirical formula.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rojas, Jimmy A. (Rojas Herrera)
Advisor dc:contributor.advisor
  • Richard Petrasso.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106770
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106770

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Rojas, Jimmy A. (Rojas Herrera). Impact of x-ray dose on the response of CR-39 nuclear track detector to 1-5.5 MeV alphas and 0.5-9.1 MeV protons for spectroscopy at the OMEGA Laser Facility and the National Ignition Facility. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106770