Back to results

Massachusetts Institute of Technology

Improving the use of commercial building HVAC systems for electric grid ancillary services

Abstract

dc:description.abstract

Increasing renewable and distributed electricity generation increases the requirement of grid-scale flexibility, often provided through ancillary services. Buildings can play a significant role in meeting this challenge by providing ancillary services with their HVAC systems. However, use of commercial HVAC systems in this way comes with significant challenges, which relate to interactions between the HVAC system and building operation, electricity markets, and electric grid operators. This thesis addresses these challenges through the use of dynamic modeling, model predictive control, and energy storage scaling techniques. First, a model of a representative VAV system is built using Modelica and simulated to characterize the system's performance while providing reserve and regulation ancillary services. It is found that reserves are provided most effectively when airflow is reduced through the terminal units, while regulation is provided most effectively when power-consuming equipment is directly controlled and has little effect on occupancy service. Next, a novel 24-hour HVAC MPC optimization problem is formulated and solved that separately accounts for a building's reserve and regulation revenue from electricity markets. Over a three-day period, it is found that ancillary service revenue can make up for 67% of HVAC energy costs when considering wholesale energy prices, and 18% when considering retail energy prices and market rules that disallow overlapping regulation and reserve capacity offerings. Second, an MPC control approach is used for the determination of opportunity costs associated with HVAC ancillary service provision, which are comparable to those of generators and could be bid into ancillary service markets. A method is developed to these costs and it is found that they can exceed $66/MWh if considering wholesale energy prices, and $93/MWh if considering retail electricity prices. Lastly, energy and power densities and costs for three thermal storage technologies available to commercial buildings are produced and compared to those of batteries. In addition, a method is developed to estimate the building HVAC reserve capacity within neighborhoods without the need for sophisticated energy simulations. In a case study involving 172 buildings, it is estimated that approximately 1100 kWh of peak hourly reserve capacity is available if thermostat setpoints are changed by 2°C.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Blum, David H. (David Henry)
Advisor dc:contributor.advisor
  • Leslie K. Norford.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106404
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106404

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Blum, David H. (David Henry). Improving the use of commercial building HVAC systems for electric grid ancillary services. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106404