{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/106125"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/106125","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Predicting hyperlactatemia in the ICU","abstract":"Sepsis, which occurs when an infection leads to a systemic inflammatory response, is believed to contribute to one in two to three hospital deaths in the United States. Using the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC II) database of electronic medical records from Boston's Beth Israel Deaconess Medical Center (BIDMC), we worked to characterize sepsis at BIDMC's intensive care units (ICUs). Additionally, we developed a real-time algorithm to stratify patients with infectious complaints into different risk categories for progressing to septic shock. From arterial blood pressure waveform trends collected from bedside monitors and readily available among patients with an arterial catheter, high-resolution time signals of heart rate and arterial blood pressure measurements, as well as estimates of cardiac output and total peripheral resistance, we developed a variety of classifiers to place patients in risk categories based on serum lactate levels, a proxy for hypoperfusion and imminent circulatory shock.","abstract_html":"Sepsis, which occurs when an infection leads to a systemic inflammatory response, is believed to contribute to one in two to three hospital deaths in the United States. Using the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC II) database of electronic medical records from Boston&#x27;s Beth Israel Deaconess Medical Center (BIDMC), we worked to characterize sepsis at BIDMC&#x27;s intensive care units (ICUs). Additionally, we developed a real-time algorithm to stratify patients with infectious complaints into different risk categories for progressing to septic shock. From arterial blood pressure waveform trends collected from bedside monitors and readily available among patients with an arterial catheter, high-resolution time signals of heart rate and arterial blood pressure measurements, as well as estimates of cardiac output and total peripheral resistance, we developed a variety of classifiers to place patients in risk categories based on serum lactate levels, a proxy for hypoperfusion and imminent circulatory shock.","abstract_has_math":false,"creators":["Dunitz, Max (Max H.)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Thomas Heldt and George Verghese."],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-07-22T22:20:59Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/106125","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Thomas Heldt and George Verghese."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Dunitz, Max (Max H.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-12-22T16:30:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-12-22T16:30:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/106125"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 107-127)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Sepsis, which occurs when an infection leads to a systemic inflammatory response, is believed to contribute to one in two to three hospital deaths in the United States. Using the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC II) database of electronic medical records from Boston's Beth Israel Deaconess Medical Center (BIDMC), we worked to characterize sepsis at BIDMC's intensive care units (ICUs). Additionally, we developed a real-time algorithm to stratify patients with infectious complaints into different risk categories for progressing to septic shock. From arterial blood pressure waveform trends collected from bedside monitors and readily available among patients with an arterial catheter, high-resolution time signals of heart rate and arterial blood pressure measurements, as well as estimates of cardiac output and total peripheral resistance, we developed a variety of classifiers to place patients in risk categories based on serum lactate levels, a proxy for hypoperfusion and imminent circulatory shock."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M. Eng."]},{"key":"dc:title","label":"Title","values":["Predicting hyperlactatemia in the ICU"]}]}],"canonical_facts":{"dc:contributor.advisor":["Thomas Heldt and George Verghese."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Dunitz, Max (Max H.)"],"dc:date.accessioned":["2016-12-22T16:30:00Z"],"dc:date.available":["2016-12-22T16:30:00Z"],"dc:date.issued":["2016"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 107-127)."],"dc:description.abstract":["Sepsis, which occurs when an infection leads to a systemic inflammatory response, is believed to contribute to one in two to three hospital deaths in the United States. Using the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC II) database of electronic medical records from Boston's Beth Israel Deaconess Medical Center (BIDMC), we worked to characterize sepsis at BIDMC's intensive care units (ICUs). Additionally, we developed a real-time algorithm to stratify patients with infectious complaints into different risk categories for progressing to septic shock. From arterial blood pressure waveform trends collected from bedside monitors and readily available among patients with an arterial catheter, high-resolution time signals of heart rate and arterial blood pressure measurements, as well as estimates of cardiac output and total peripheral resistance, we developed a variety of classifiers to place patients in risk categories based on serum lactate levels, a proxy for hypoperfusion and imminent circulatory shock."],"dc:description.degree":["M. Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/106125"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Predicting hyperlactatemia in the ICU"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:20:59Z"}