Back to results

Massachusetts Institute of Technology

0.3V biopotential sensor interface for stress monitoring

Abstract

dc:description.abstract

Miniaturized sensor nodes have a very tight power budget, especially in the case of implantables and health monitoring devices that require long operation lifetime. Exploiting low-voltage techniques in analog design can enable further power savings, which has not been explored much. However, for conventional analog-front-end (AFE) topologies, voltage scaling could potentially bring several limitations to the important performance metrics such as the linearity, robustness and the power-efficiency. This thesis work describes the design of a 0.3V biopotential sensor interface for stress monitoring applications, which achieves state-of-the-art power-efficiency, and ensures enough circuit reliability with reduced dynamic range requirement. The proposed sensor interface consists of an amplifier and an analog-to-digital converter (ADC). The simulated amplifier achieves 0.95nW power consumption with a power-efficiency-factor (PEF) of 1.57. With this power budget, the amplifier also presents large signal cancellation capability in order to reject the motion artifacts. The system, together with the ADC consumes 4.1nW power, and has an area of 0.2mm2 which makes the sensor interface suitable for wearable and implantable devices. The chip has been submitted for fabrication in a low power 65nm digital CMOS process, and the simulation results are presented.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Orguc, Sirma
Advisor dc:contributor.advisor
  • Anantha P. Chandrakasan.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106085
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106085

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Orguc, Sirma. 0.3V biopotential sensor interface for stress monitoring. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106085